Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 15:13:21
Create:
Description #3330015
Value: Type of heating boiler: gas, max. thermal power: 20 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3330016
Value: Gas, condensing
Create:
Burner #3330017
Value: Gas
Create:
Number of circuits #3330018
Value: Double-circuit
Create:
Thermal power #3330019
Value: 3.40 - 20 kW
Create:
Thermal load #3330020
Value: 3.50 - 20.60 kW
Create:
The combustion chamber #3330021
Value: Closed
Create:
Efficiency #3330022
Value: 105.8 %
Create:
Control #3330023
Value: Electronic
Create:
Installation #3330024
Value: Wall-mounted
Create:
Primary heat exchanger material #3330025
Value: Stainless steel
Create:
Mains voltage #3330026
Value: Single-phase
Create:
Peculiarities #3330027
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
The volume of the built-in boiler #3330028
Value: 40 l
Create:
Expansion tank volume #3330029
Value: 7.5 l
Create:
Equipment #3330030
Value: Built-in boiler, display
Create:
Fuel #3330031
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3330032
Value: 2.61 cu. m/hour
Create:
LPG consumption #3330033
Value: 1.92 kg/hour
Create:
Nominal pressure of natural gas #3330034
Value: 5 - 20 mbar
Create:
Permissible LPG pressure #3330035
Value: 37 mbar
Create:
Heat carrier temperature #3330036
Value: 25 - 80 °C
Create:
Temperature in the DHW circuit #3330037
Value: 35 - 60 °С
Create:
Hot water capacity at t 25°C #3330038
Value: 13.8 l/min
Create:
Hot water capacity at t 35°C #3330039
Value: 9.8 l/min
Create:
Max. water pressure in the DHW circuit #3330040
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3330041
Value: 3 bar
Create:
Gas connection #3330042
Value: 3/4"
Create:
Heating circuit connection #3330043
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3330044
Value: 1/2"
Create:
Coaxial chimney diameter #3330045
Value: 60/100 mm
Create:
Dimensions WxHxD #3330046
Value: 600x950x466mm
Create:
Weight #3330047
Value: 62 kg
Create:
Additional Information #3330048
Value: Hot water productivity for the first 30 minutes at Δt
Create:
Image #6305447
URL: https://avatars.mds.yandex.net/get-mpic/3985831/img_id5964993762952197826.jpeg/orig
Create:
Image #6305448
URL: https://avatars.mds.yandex.net/get-mpic/4466428/img_id5382976929369982338.jpeg/orig
Create:
Image #6305449
URL: https://avatars.mds.yandex.net/get-mpic/5233785/img_id1740440428354452500.jpeg/orig
Create:
Image #6305450
URL: https://avatars.mds.yandex.net/get-mpic/5255532/img_id5671739768147756221.png/orig
Create:
Image #6305451
URL: https://avatars.mds.yandex.net/get-mpic/4262452/img_id8937651864353824143.jpeg/orig
Create:
Image #6305452
URL: https://avatars.mds.yandex.net/get-mpic/5253277/img_id2715106311643200268.jpeg/orig
Create:
Image #6305453
URL: https://avatars.mds.yandex.net/get-mpic/5303294/img_id5447199307341554775.jpeg/orig
Create:
Image #6305454
URL: https://avatars.mds.yandex.net/get-mpic/4012413/img_id7175278561385478481.jpeg/orig
Create:
Image #6305455
URL: https://avatars.mds.yandex.net/get-mpic/4426104/img_id2425893279169390317.jpeg/orig
Create:
Image #6305456
URL: https://avatars.mds.yandex.net/get-mpic/5281967/img_id6950344705166243746.png/orig
Create:
Image #6305457
URL: https://avatars.mds.yandex.net/get-mpic/1865974/img_id3272335987154663264.jpeg/orig
Create:
Preview image #6305458
URL: https://avatars.mds.yandex.net/get-mpic/3985831/img_id5964993762952197826.jpeg/orig
Donny Darko 30 April 2023 08:04:29
Name: Gas boiler NUVOLA DUO-TEC+ 24 GA; Catalog: Heating boilers