Change history for item: Gas boiler BAXI Luna Duo-tec E 33 double-circuit

  1. Donny Darko 07 July 2023 15:10:05
    1. Create: Description #3329253
      Value: Type of heating boiler: gas, max. thermal power: 34 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3329254
      Value: Gas, condensing
    3. Create: Burner #3329255
      Value: Gas
    4. Create: Number of circuits #3329256
      Value: Double-circuit
    5. Create: Thermal power #3329257
      Value: 4.70 - 34 kW
    6. Create: The combustion chamber #3329258
      Value: Closed
    7. Create: Efficiency #3329259
      Value: 110 %
    8. Create: Control #3329260
      Value: Electronic
    9. Create: Installation #3329261
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3329262
      Value: Stainless steel
    11. Create: Mains voltage #3329263
      Value: Single-phase
    12. Create: Peculiarities #3329264
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, water filter
    13. Create: Expansion tank volume #3329265
      Value: 8 l
    14. Create: Equipment #3329266
      Value: Display
    15. Create: Fuel #3329267
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3329268
      Value: 3.6 cu. m/hour
    17. Create: LPG consumption #3329269
      Value: 2.64 kg/h
    18. Create: Nominal pressure of natural gas #3329270
      Value: 20 mbar
    19. Create: Permissible LPG pressure #3329271
      Value: 37 mbar
    20. Create: Heat carrier temperature #3329272
      Value: 25 - 80 °C
    21. Create: Temperature in the DHW circuit #3329273
      Value: 35 - 60 °С
    22. Create: Hot water capacity at t 25°C #3329274
      Value: 18.9 l/min
    23. Create: Hot water capacity at t 35°C #3329275
      Value: 13.5 l/min
    24. Create: Max. water pressure in the DHW circuit #3329276
      Value: 8 bar
    25. Create: Max. water pressure in the heating circuit #3329277
      Value: 3 bar
    26. Create: Gas connection #3329278
      Value: 3/4"
    27. Create: Heating circuit connection #3329279
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3329280
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3329281
      Value: 60/100 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3329282
      Value: Yes
    31. Create: Dimensions WxHxD #3329283
      Value: 450x763x345 mm
    32. Create: Weight #3329284
      Value: 39.5 kg
    33. Create: Image #6305247
      URL: https://avatars.mds.yandex.net/get-mpic/3725687/img_id1152845834063185020.jpeg/orig
    34. Create: Image #6305248
      URL: https://avatars.mds.yandex.net/get-mpic/4450422/img_id374991650495884747.jpeg/orig
    35. Create: Image #6305249
      URL: https://avatars.mds.yandex.net/get-mpic/5306939/img_id5736589880449811702.jpeg/orig
    36. Create: Image #6305250
      URL: https://avatars.mds.yandex.net/get-mpic/2008488/img_id2061878709471613537.jpeg/orig
    37. Create: Image #6305251
      URL: https://avatars.mds.yandex.net/get-mpic/5217165/img_id8117712576411280737.jpeg/orig
    38. Create: Image #6305252
      URL: https://avatars.mds.yandex.net/get-mpic/1859594/img_id3924913222974288653.jpeg/orig
    39. Create: Image #6305253
      URL: https://avatars.mds.yandex.net/get-mpic/1656415/img_id5594020505852087110.png/orig
    40. Create: Image #6305254
      URL: https://avatars.mds.yandex.net/get-mpic/4465918/img_id937701857245759309.jpeg/orig
    41. Create: Image #6305255
      URL: https://avatars.mds.yandex.net/get-mpic/3934197/img_id1293674722715496956.jpeg/orig
    42. Create: Preview image #6305256
      URL: https://avatars.mds.yandex.net/get-mpic/3725687/img_id1152845834063185020.jpeg/orig
  2. Donny Darko 30 April 2023 08:04:17
    Name: Gas boiler BAXI Luna Duo-tec E 33 double-circuit; Catalog: Heating boilers