Change history for item: Gas boiler BAXI Luna Duo-tec E 40 double-circuit

  1. Donny Darko 07 July 2023 15:10:02
    1. Create: Description #3329221
      Value: Type of heating boiler: gas, max. heating power: 41.20 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3329222
      Value: Gas, condensing
    3. Create: Burner #3329223
      Value: Gas
    4. Create: Number of circuits #3329224
      Value: Double-circuit
    5. Create: Thermal power #3329225
      Value: 5.70 - 41.20 kW
    6. Create: The combustion chamber #3329226
      Value: Closed
    7. Create: Efficiency #3329227
      Value: 110 %
    8. Create: Control #3329228
      Value: Electronic
    9. Create: Installation #3329229
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3329230
      Value: Stainless steel
    11. Create: Mains voltage #3329231
      Value: Single-phase
    12. Create: Peculiarities #3329232
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, water filter
    13. Create: Expansion tank volume #3329233
      Value: 8 l
    14. Create: Equipment #3329234
      Value: Display
    15. Create: Fuel #3329235
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3329236
      Value: 3.36 cu. m/hour
    17. Create: LPG consumption #3329237
      Value: 3.2 kg/hour
    18. Create: Nominal pressure of natural gas #3329238
      Value: 20 mbar
    19. Create: Permissible LPG pressure #3329239
      Value: 37 mbar
    20. Create: Heat carrier temperature #3329240
      Value: 25 - 80 °C
    21. Create: Temperature in the DHW circuit #3329241
      Value: 35 - 60 °С
    22. Create: Hot water capacity at t 25°C #3329242
      Value: 22.9 l/min
    23. Create: Hot water capacity at t 35°C #3329243
      Value: 16.4 l/min
    24. Create: Max. water pressure in the DHW circuit #3329244
      Value: 8 bar
    25. Create: Max. water pressure in the heating circuit #3329245
      Value: 3 bar
    26. Create: Gas connection #3329246
      Value: 3/4"
    27. Create: Heating circuit connection #3329247
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3329248
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3329249
      Value: 60/100 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3329250
      Value: Yes
    31. Create: Dimensions WxHxD #3329251
      Value: 450x763x345 mm
    32. Create: Weight #3329252
      Value: 41 kg
    33. Create: Image #6305240
      URL: https://avatars.mds.yandex.net/get-mpic/4705079/img_id2215947363386204645.jpeg/orig
    34. Create: Image #6305241
      URL: https://avatars.mds.yandex.net/get-mpic/5306939/img_id5736589880449811702.jpeg/orig
    35. Create: Image #6305242
      URL: https://avatars.mds.yandex.net/get-mpic/5252617/img_id8599389683808082181.jpeg/orig
    36. Create: Image #6305243
      URL: https://avatars.mds.yandex.net/get-mpic/5234495/img_id1256500909080908493.jpeg/orig
    37. Create: Image #6305244
      URL: https://avatars.mds.yandex.net/get-mpic/7979706/img_id7212624843762727481.jpeg/orig
    38. Create: Image #6305245
      URL: https://avatars.mds.yandex.net/get-mpic/5235101/img_id1249133605912611705.png/orig
    39. Create: Preview image #6305246
      URL: https://avatars.mds.yandex.net/get-mpic/4705079/img_id2215947363386204645.jpeg/orig
  2. Donny Darko 30 April 2023 08:04:16
    Name: Gas boiler BAXI Luna Duo-tec E 40 double-circuit; Catalog: Heating boilers