Description #3328822
Value: Type of heating boiler: gas, max. heating power: 30.90 kW, number of circuits: double-circuit, location: floor, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3328823
Value: Gas, convection
Create:
Burner #3328824
Value: Gas
Create:
Number of circuits #3328825
Value: Double-circuit
Create:
Thermal power #3328826
Value: 15.80 - 30.90 kW
Create:
Thermal load #3328827
Value: 18 - 34.30 kW
Create:
The combustion chamber #3328828
Value: Closed
Create:
Control #3328829
Value: Electronic
Create:
Installation #3328830
Value: Floor
Create:
Primary heat exchanger material #3328831
Value: Cast iron
Create:
Mains voltage #3328832
Value: Single-phase
Create:
Peculiarities #3328833
Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, connector for external control, thermometer
Create:
The volume of the built-in boiler #3328834
Value: 100 l
Create:
Expansion tank volume #3328835
Value: 10 l
Create:
Equipment #3328836
Value: Built-in boiler
Create:
Fuel #3328837
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3328838
Value: 3.63 cu. m/hour
Create:
Nominal pressure of natural gas #3328839
Value: 20 mbar
Create:
Permissible LPG pressure #3328840
Value: 37 mbar
Create:
Heat carrier temperature #3328841
Value: 30 - 85 °С
Create:
Temperature in the DHW circuit #3328842
Value: 5 - 65 °С
Create:
Hot water capacity at t 35°C #3328843
Value: 12.6 l/min
Create:
Max. water pressure in the DHW circuit #3328844
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3328845
Value: 3 bar
Create:
Gas connection #3328846
Value: 1/2"
Create:
Heating circuit connection #3328847
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3328848
Value: 1/2"
Create:
Coaxial chimney diameter #3328849
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3328850
Value: Yes
Create:
Dimensions WxHxD #3328851
Value: 600x1490x642mm
Create:
Weight #3328852
Value: 216 kg
Create:
Additional Information #3328853
Value: DHW safety valve
Create:
Image #6305099
URL: https://avatars.mds.yandex.net/get-mpic/1937077/img_id3971450194184249820/orig
Create:
Preview image #6305100
URL: https://avatars.mds.yandex.net/get-mpic/1937077/img_id3971450194184249820/orig
Donny Darko 30 April 2023 08:04:13
Name: Gas boiler BAXI GALAXY 310 Fi 30.9 kW double-circuit; Catalog: Heating boilers