Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 15:09:01
Create:
Description #3328788
Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3328789
Value: Gas, convection
Create:
Burner #3328790
Value: Gas
Create:
Number of circuits #3328791
Value: Double-circuit
Create:
Thermal power #3328792
Value: 9.30 - 24 kW
Create:
Thermal load #3328793
Value: 10.60 - 25.80 kW
Create:
The combustion chamber #3328794
Value: Closed
Create:
Efficiency #3328795
Value: 92.9 %
Create:
Control #3328796
Value: Electronic
Create:
Installation #3328797
Value: Wall-mounted
Create:
Primary heat exchanger material #3328798
Value: Copper
Create:
Secondary heat exchanger material #3328799
Value: Copper
Create:
Mains voltage #3328800
Value: Single-phase
Create:
Peculiarities #3328801
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
Expansion tank volume #3328802
Value: 6 l
Create:
Equipment #3328803
Value: Display
Create:
Fuel #3328804
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3328805
Value: 2.73 cu. m/hour
Create:
LPG consumption #3328806
Value: 2 kg/hour
Create:
Nominal pressure of natural gas #3328807
Value: 20 mbar
Create:
Permissible LPG pressure #3328808
Value: 37 mbar
Create:
Heat carrier temperature #3328809
Value: 30 - 85 °С
Create:
Temperature in the DHW circuit #3328810
Value: 35 - 60 °С
Create:
Hot water capacity at t 25°C #3328811
Value: 13.7 l/min
Create:
Hot water capacity at t 35°C #3328812
Value: 9.8 l/min
Create:
Max. water pressure in the DHW circuit #3328813
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3328814
Value: 3 bar
Create:
Gas connection #3328815
Value: 3/4"
Create:
Heating circuit connection #3328816
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3328817
Value: 1/2"
Create:
Coaxial chimney diameter #3328818
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3328819
Value: Yes
Create:
Dimensions WxHxD #3328820
Value: 400x730x299 mm
Create:
Weight #3328821
Value: 30 kg
Create:
Image #6305087
URL: https://avatars.mds.yandex.net/get-mpic/4547325/img_id9219719238871049951.jpeg/orig
Create:
Image #6305088
URL: https://avatars.mds.yandex.net/get-mpic/5299050/img_id8631532081408995386.png/orig
Create:
Image #6305089
URL: https://avatars.mds.yandex.net/get-mpic/1865278/img_id732757450915866412.png/orig
Create:
Image #6305090
URL: https://avatars.mds.yandex.net/get-mpic/4367383/img_id2176504289678495699.jpeg/orig
Create:
Image #6305091
URL: https://avatars.mds.yandex.net/get-mpic/5234464/img_id1391021901445388135.jpeg/orig
Create:
Image #6305092
URL: https://avatars.mds.yandex.net/get-mpic/1636931/img_id2728420364359905878.jpeg/orig
Create:
Image #6305093
URL: https://avatars.mds.yandex.net/get-mpic/5217715/img_id3696148657315693825.jpeg/orig
Create:
Image #6305094
URL: https://avatars.mds.yandex.net/get-mpic/3765589/img_id6498355512978318256.jpeg/orig
Create:
Image #6305095
URL: https://avatars.mds.yandex.net/get-mpic/1901647/img_id5034523233148949597.jpeg/orig
Create:
Image #6305096
URL: https://avatars.mds.yandex.net/get-mpic/4544069/img_id8478857491085575509.jpeg/orig
Create:
Image #6305097
URL: https://avatars.mds.yandex.net/get-mpic/4353087/img_id2565523828372725229.png/orig
Create:
Preview image #6305098
URL: https://avatars.mds.yandex.net/get-mpic/4547325/img_id9219719238871049951.jpeg/orig
Donny Darko 30 April 2023 08:04:13
Name: Gas boiler BAXI ECO Home 24F 24 kW double-circuit; Catalog: Heating boilers