Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 15:08:58
Create:
Description #3328755
Value: Type of heating boiler: gas, max. thermal power: 14 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3328756
Value: Gas, convection
Create:
Burner #3328757
Value: Gas
Create:
Number of circuits #3328758
Value: Double-circuit
Create:
Thermal power #3328759
Value: 9.30 - 14 kW
Create:
Thermal load #3328760
Value: 10.60 - 15.70 kW
Create:
The combustion chamber #3328761
Value: Closed
Create:
Efficiency #3328762
Value: 92.5 %
Create:
Control #3328763
Value: Electronic
Create:
Installation #3328764
Value: Wall-mounted
Create:
Primary heat exchanger material #3328765
Value: Copper
Create:
Mains voltage #3328766
Value: Single-phase
Create:
Peculiarities #3328767
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
Expansion tank volume #3328768
Value: 6 l
Create:
Equipment #3328769
Value: Display
Create:
Fuel #3328770
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3328771
Value: 1.66 cu. m/hour
Create:
LPG consumption #3328772
Value: 1.22 kg/hour
Create:
Nominal pressure of natural gas #3328773
Value: 20 mbar
Create:
Permissible LPG pressure #3328774
Value: 37 mbar
Create:
Heat carrier temperature #3328775
Value: 30 - 85 °С
Create:
Temperature in the DHW circuit #3328776
Value: 35 - 60 °С
Create:
Hot water capacity at t 25°C #3328777
Value: 13.7 l/min
Create:
Hot water capacity at t 35°C #3328778
Value: 9.8 l/min
Create:
Max. water pressure in the DHW circuit #3328779
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3328780
Value: 3 bar
Create:
Gas connection #3328781
Value: 3/4"
Create:
Heating circuit connection #3328782
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3328783
Value: 1/2"
Create:
Coaxial chimney diameter #3328784
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3328785
Value: Yes
Create:
Dimensions WxHxD #3328786
Value: 400x730x299 mm
Create:
Weight #3328787
Value: 30 kg
Create:
Image #6305085
URL: https://avatars.mds.yandex.net/get-mpic/4343007/img_id9033848099884363541.jpeg/orig
Create:
Preview image #6305086
URL: https://avatars.mds.yandex.net/get-mpic/4343007/img_id9033848099884363541.jpeg/orig
Donny Darko 30 April 2023 08:04:13
Name: Gas boiler BAXI ECO Home 14F 14 kW double-circuit; Catalog: Heating boilers