Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 15:08:54
Create:
Description #3328721
Value: Type of heating boiler: gas, max. thermal power: 10 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3328722
Value: Gas, convection
Create:
Burner #3328723
Value: Gas
Create:
Number of circuits #3328724
Value: Double-circuit
Create:
Max. thermal power #3328725
Value: 10 kW
Create:
Max. thermal load #3328726
Value: 11.30 kW
Create:
The combustion chamber #3328727
Value: Closed
Create:
Efficiency #3328728
Value: 90.8 %
Create:
Control #3328729
Value: Electronic
Create:
Installation #3328730
Value: Wall-mounted
Create:
Primary heat exchanger material #3328731
Value: Copper
Create:
Secondary heat exchanger material #3328732
Value: Stainless steel
Create:
Mains voltage #3328733
Value: Single-phase
Create:
Peculiarities #3328734
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
Expansion tank volume #3328735
Value: 6 l
Create:
Equipment #3328736
Value: Display
Create:
Fuel #3328737
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3328738
Value: 1.19 cu. m/hour
Create:
LPG consumption #3328739
Value: 0.88 kg/hour
Create:
Nominal pressure of natural gas #3328740
Value: 20 mbar
Create:
Permissible LPG pressure #3328741
Value: 37 mbar
Create:
Heat carrier temperature #3328742
Value: 30 - 85 °С
Create:
Temperature in the DHW circuit #3328743
Value: 35 - 60 °С
Create:
Hot water capacity at t 25°C #3328744
Value: 13.7 l/min
Create:
Hot water capacity at t 35°C #3328745
Value: 9.8 l/min
Create:
Max. water pressure in the DHW circuit #3328746
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3328747
Value: 3 bar
Create:
Gas connection #3328748
Value: 3/4"
Create:
Heating circuit connection #3328749
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3328750
Value: 1/2"
Create:
Coaxial chimney diameter #3328751
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3328752
Value: Yes
Create:
Dimensions WxHxD #3328753
Value: 400x730x299 mm
Create:
Weight #3328754
Value: 30 kg
Create:
Image #6305083
URL: https://avatars.mds.yandex.net/get-mpic/4343092/img_id4544916082249287392.jpeg/orig
Create:
Preview image #6305084
URL: https://avatars.mds.yandex.net/get-mpic/4343092/img_id4544916082249287392.jpeg/orig
Donny Darko 30 April 2023 08:04:12
Name: Gas boiler BAXI ECO Home 10F 10 kW double-circuit; Catalog: Heating boilers