Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 15:07:08
Create:
Description #3328062
Value: Type of heating boiler: gas, max. thermal power: 28 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3328063
Value: Gas, convection
Create:
Burner #3328064
Value: Gas
Create:
Number of circuits #3328065
Value: Double-circuit
Create:
Thermal power #3328066
Value: 10.40 - 28 kW
Create:
Thermal load #3328067
Value: 11.90 - 31.10 kW
Create:
The combustion chamber #3328068
Value: Closed
Create:
Efficiency #3328069
Value: 90.3 %
Create:
Control #3328070
Value: Electronic
Create:
Installation #3328071
Value: Wall-mounted
Create:
Primary heat exchanger material #3328072
Value: Copper
Create:
Secondary heat exchanger material #3328073
Value: Stainless steel
Create:
Mains voltage #3328074
Value: Single-phase
Create:
Peculiarities #3328075
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
The volume of the built-in boiler #3328076
Value: 60 l
Create:
Expansion tank volume #3328077
Value: 7.5 l
Create:
Equipment #3328078
Value: Built-in boiler
Create:
Fuel #3328079
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3328080
Value: 3.29 cu. m/hour
Create:
LPG consumption #3328081
Value: 2.45 kg/hour
Create:
Nominal pressure of natural gas #3328082
Value: 20 - 30 mbar
Create:
Permissible LPG pressure #3328083
Value: 37 mbar
Create:
Heat carrier temperature #3328084
Value: 30 - 85 °С
Create:
Temperature in the DHW circuit #3328085
Value: 5 - 60 °С
Create:
Hot water capacity at t 25°C #3328086
Value: 16.1 l/min
Create:
Hot water capacity at t 35°C #3328087
Value: 11.5 l/min
Create:
Max. water pressure in the DHW circuit #3328088
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3328089
Value: 3 bar
Create:
Heating circuit connection #3328090
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3328091
Value: 1/2"
Create:
Coaxial chimney diameter #3328092
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3328093
Value: Yes
Create:
Dimensions WxHxD #3328094
Value: 600x950x466mm
Create:
Weight #3328095
Value: 70 kg
Create:
Image #6304858
URL: https://avatars.mds.yandex.net/get-mpic/4412310/img_id3321948361310983002.jpeg/orig
Create:
Preview image #6304859
URL: https://avatars.mds.yandex.net/get-mpic/4412310/img_id3321948361310983002.jpeg/orig
Donny Darko 30 April 2023 08:04:06
Name: Gas boiler BAXI NUVOLA 280 Fi 28 kW double-circuit; Catalog: Heating boilers