Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 15:06:09
Create:
Description #3327663
Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
Create:
Type of heating boiler #3327664
Value: Gas, convection
Create:
Burner #3327665
Value: Gas
Create:
Number of circuits #3327666
Value: Double-circuit
Create:
Thermal power #3327667
Value: 9.30 - 24 kW
Create:
Thermal load #3327668
Value: 10.60 - 26.30 kW
Create:
The combustion chamber #3327669
Value: Open
Create:
Efficiency #3327670
Value: 90.3 %
Create:
Control #3327671
Value: Electronic
Create:
Installation #3327672
Value: Wall-mounted
Create:
Primary heat exchanger material #3327673
Value: Copper
Create:
Secondary heat exchanger material #3327674
Value: Stainless steel
Create:
Mains voltage #3327675
Value: Single-phase
Create:
Peculiarities #3327676
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
Expansion tank volume #3327677
Value: 8 l
Create:
Fuel #3327678
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3327679
Value: 2.7 cu. m/hour
Create:
LPG consumption #3327680
Value: 2.04 kg/h
Create:
Nominal pressure of natural gas #3327681
Value: 5 - 20 mbar
Create:
Permissible LPG pressure #3327682
Value: 37 mbar
Create:
Heat carrier temperature #3327683
Value: 30 - 85 °С
Create:
Temperature in the DHW circuit #3327684
Value: 35 - 65 °С
Create:
Hot water capacity at t 25°C #3327685
Value: 13.7 l/min
Create:
Hot water capacity at t 35°C #3327686
Value: 9.8 l/min
Create:
Max. water pressure in the DHW circuit #3327687
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3327688
Value: 3 bar
Create:
Gas connection #3327689
Value: 3/4"
Create:
Heating circuit connection #3327690
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3327691
Value: 1/2"
Create:
Chimney diameter #3327692
Value: 120 mm
Create:
Dimensions WxHxD #3327693
Value: 450x760x345 mm
Create:
Weight #3327694
Value: 37.5 kg
Create:
Image #6304830
URL: https://avatars.mds.yandex.net/get-mpic/1620389/img_id8344793496030612834/orig
Create:
Preview image #6304831
URL: https://avatars.mds.yandex.net/get-mpic/1620389/img_id8344793496030612834/orig
Donny Darko 30 April 2023 08:04:02
Name: Gas boiler BAXI LUNA max 240 i 24 kW double-circuit; Catalog: Heating boilers