Change history for item: Gas boiler BAXI MAIN 24 i 24 kW double-circuit

  1. Donny Darko 07 July 2023 15:05:45
    1. Create: Description #3327480
      Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3327481
      Value: Gas, convection
    3. Create: Burner #3327482
      Value: Gas
    4. Create: Number of circuits #3327483
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3327484
      Value: 9.30 - 24 kW
    6. Create: Thermal load #3327485
      Value: 10.60 - 26.30 kW
    7. Create: The combustion chamber #3327486
      Value: Open
    8. Create: Efficiency #3327487
      Value: 90.3 %
    9. Create: Control #3327488
      Value: Electronic
    10. Create: Installation #3327489
      Value: Wall-mounted
    11. Create: Mains voltage #3327490
      Value: Single-phase
    12. Create: Peculiarities #3327491
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3327492
      Value: 8 l
    14. Create: Fuel #3327493
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3327494
      Value: 2.78 cu. m/hour
    16. Create: LPG consumption #3327495
      Value: 2.07 kg/h
    17. Create: Nominal pressure of natural gas #3327496
      Value: 5 - 20 mbar
    18. Create: Permissible LPG pressure #3327497
      Value: 37 mbar
    19. Create: Heat carrier temperature #3327498
      Value: 35 - 80 °С
    20. Create: Temperature in the DHW circuit #3327499
      Value: 35 - 55 °С
    21. Create: Hot water capacity at t 25°C #3327500
      Value: 13.7 l/min
    22. Create: Hot water capacity at t 35°C #3327501
      Value: 9.8 l/min
    23. Create: Max. water pressure in the DHW circuit #3327502
      Value: 8 bar
    24. Create: Max. water pressure in the heating circuit #3327503
      Value: 3 bar
    25. Create: Gas connection #3327504
      Value: 3/4"
    26. Create: Heating circuit connection #3327505
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3327506
      Value: 1/2"
    28. Create: Chimney diameter #3327507
      Value: 120 mm
    29. Create: Dimensions WxHxD #3327508
      Value: 400x734x317 mm
    30. Create: Weight #3327509
      Value: 29 kg
    31. Create: Image #6304816
      URL: https://avatars.mds.yandex.net/get-mpic/4462738/img_id2482627696475820101.jpeg/orig
    32. Create: Preview image #6304817
      URL: https://avatars.mds.yandex.net/get-mpic/4462738/img_id2482627696475820101.jpeg/orig
  2. Donny Darko 30 April 2023 08:04:00
    Name: Gas boiler BAXI MAIN 24 i 24 kW double-circuit; Catalog: Heating boilers