Change history for item: Gas boiler BAXI MAIN 24 Fi

  1. Donny Darko 07 July 2023 15:05:40
    1. Create: Description #3327449
      Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3327450
      Value: Gas, convection
    3. Create: Burner #3327451
      Value: Gas
    4. Create: Number of circuits #3327452
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3327453
      Value: 9.30 - 24 kW
    6. Create: Thermal load #3327454
      Value: 10.60 - 26.30 kW
    7. Create: The combustion chamber #3327455
      Value: Closed
    8. Create: Efficiency #3327456
      Value: 90.3 %
    9. Create: Control #3327457
      Value: Electronic
    10. Create: Installation #3327458
      Value: Wall-mounted
    11. Create: Mains voltage #3327459
      Value: Single-phase
    12. Create: Peculiarities #3327460
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3327461
      Value: 8 l
    14. Create: Fuel #3327462
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3327463
      Value: 2.78 cu. m/hour
    16. Create: LPG consumption #3327464
      Value: 2.07 kg/h
    17. Create: Nominal pressure of natural gas #3327465
      Value: 5 - 20 mbar
    18. Create: Permissible LPG pressure #3327466
      Value: 37 mbar
    19. Create: Heat carrier temperature #3327467
      Value: 35 - 80 °С
    20. Create: Temperature in the DHW circuit #3327468
      Value: 35 - 55 °С
    21. Create: Hot water capacity at t 25°C #3327469
      Value: 13.7 l/min
    22. Create: Hot water capacity at t 35°C #3327470
      Value: 9.8 l/min
    23. Create: Max. water pressure in the DHW circuit #3327471
      Value: 8 bar
    24. Create: Max. water pressure in the heating circuit #3327472
      Value: 3 bar
    25. Create: Gas connection #3327473
      Value: 3/4"
    26. Create: Heating circuit connection #3327474
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3327475
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3327476
      Value: 60/100 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3327477
      Value: Yes
    30. Create: Dimensions WxHxD #3327478
      Value: 400x734x317 mm
    31. Create: Weight #3327479
      Value: 33.5 kg
    32. Create: Image #6304814
      URL: https://avatars.mds.yandex.net/get-mpic/4101287/img_id1902487879598075311.jpeg/orig
    33. Create: Preview image #6304815
      URL: https://avatars.mds.yandex.net/get-mpic/4101287/img_id1902487879598075311.jpeg/orig
  2. Donny Darko 30 April 2023 08:04:00
    Name: Gas boiler BAXI MAIN 24 Fi; Catalog: Heating boilers