Change history for item: Gas boiler BAXI PRIME HT 240 21.6 kW double-circuit

  1. Donny Darko 07 July 2023 15:04:33
    1. Create: Description #3326985
      Value: Type of heating boiler: gas, max. heating power: 21.60 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3326986
      Value: Gas, condensing
    3. Create: Burner #3326987
      Value: Gas
    4. Create: Number of circuits #3326988
      Value: Double-circuit
    5. Create: Thermal power #3326989
      Value: 6.80 - 21.60 kW
    6. Create: Thermal load #3326990
      Value: 7 - 20.50 kW
    7. Create: The combustion chamber #3326991
      Value: Closed
    8. Create: Efficiency #3326992
      Value: 105.1 %
    9. Create: Control #3326993
      Value: Electronic
    10. Create: Installation #3326994
      Value: Wall-mounted
    11. Create: Mains voltage #3326995
      Value: Single-phase
    12. Create: Peculiarities #3326996
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    13. Create: Expansion tank volume #3326997
      Value: 8 l
    14. Create: Equipment #3326998
      Value: Display
    15. Create: Fuel #3326999
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3327000
      Value: 2.61 cu. m/hour
    17. Create: LPG consumption #3327001
      Value: 1.92 kg/hour
    18. Create: Nominal pressure of natural gas #3327002
      Value: 20 mbar
    19. Create: Permissible LPG pressure #3327003
      Value: 37 mbar
    20. Create: Heat carrier temperature #3327004
      Value: 25 - 80 °C
    21. Create: Temperature in the DHW circuit #3327005
      Value: 35 - 60 °С
    22. Create: Hot water capacity at t 25°C #3327006
      Value: 13.8 l/min
    23. Create: Hot water capacity at t 35°C #3327007
      Value: 9.8 l/min
    24. Create: Max. water pressure in the DHW circuit #3327008
      Value: 8 bar
    25. Create: Max. water pressure in the heating circuit #3327009
      Value: 3 bar
    26. Create: Gas connection #3327010
      Value: 3/4"
    27. Create: Heating circuit connection #3327011
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3327012
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3327013
      Value: 60/100 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3327014
      Value: Yes
    31. Create: Dimensions WxHxD #3327015
      Value: 450x763x345 mm
    32. Create: Weight #3327016
      Value: 44 kg
    33. Create: Image #6304782
      URL: https://avatars.mds.yandex.net/get-mpic/3694390/img_id7894868222028201957.jpeg/orig
    34. Create: Preview image #6304783
      URL: https://avatars.mds.yandex.net/get-mpic/3694390/img_id7894868222028201957.jpeg/orig
  2. Donny Darko 30 April 2023 08:03:56
    Name: Gas boiler BAXI PRIME HT 240 21.6 kW double-circuit; Catalog: Heating boilers