Change history for item: Gas boiler BAXI NUVOLA-3 Comfort HT 330

  1. Donny Darko 07 July 2023 15:04:29
    1. Create: Description #3326954
      Value: Type of heating boiler: gas, max. thermal power: 28 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3326955
      Value: Gas, condensing
    3. Create: Burner #3326956
      Value: Gas
    4. Create: Number of circuits #3326957
      Value: Double-circuit
    5. Create: Thermal power #3326958
      Value: 9.40 - 28 kW
    6. Create: Thermal load #3326959
      Value: 9.70 - 28.90 kW
    7. Create: The combustion chamber #3326960
      Value: Closed
    8. Create: Control #3326961
      Value: Electronic
    9. Create: Installation #3326962
      Value: Wall-mounted
    10. Create: Mains voltage #3326963
      Value: Single-phase
    11. Create: Peculiarities #3326964
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    12. Create: Expansion tank volume #3326965
      Value: 10 l
    13. Create: Equipment #3326966
      Value: Display, room thermostat
    14. Create: Fuel #3326967
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3326968
      Value: 3.59 cu. m/hour
    16. Create: LPG consumption #3326969
      Value: 2.64 kg/h
    17. Create: Nominal pressure of natural gas #3326970
      Value: 20 mbar
    18. Create: Permissible LPG pressure #3326971
      Value: 37 mbar
    19. Create: Heat carrier temperature #3326972
      Value: 25 - 80 °C
    20. Create: Temperature in the DHW circuit #3326973
      Value: 35 - 60 °С
    21. Create: Hot water capacity at t 25°C #3326974
      Value: 18.9 l/min
    22. Create: Hot water capacity at t 35°C #3326975
      Value: 15.8 l/min
    23. Create: Max. water pressure in the DHW circuit #3326976
      Value: 8 bar
    24. Create: Max. water pressure in the heating circuit #3326977
      Value: 3 bar
    25. Create: Gas connection #3326978
      Value: 3/4"
    26. Create: Heating circuit connection #3326979
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3326980
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3326981
      Value: 60/100 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3326982
      Value: Yes
    30. Create: Dimensions WxHxD #3326983
      Value: 600x950x466mm
    31. Create: Weight #3326984
      Value: 67 kg
    32. Create: Image #6304779
      URL: https://avatars.mds.yandex.net/get-mpic/3721790/img_id2591177260809333536.jpeg/orig
    33. Create: Image #6304780
      URL: https://avatars.mds.yandex.net/get-mpic/5131700/img_id2807728002933462957.jpeg/orig
    34. Create: Preview image #6304781
      URL: https://avatars.mds.yandex.net/get-mpic/3721790/img_id2591177260809333536.jpeg/orig
  2. Donny Darko 30 April 2023 08:03:55
    Name: Gas boiler BAXI NUVOLA-3 Comfort HT 330; Catalog: Heating boilers