Change history for item: Gas boiler BAXI NUVOLA-3 Comfort HT 240

  1. Donny Darko 07 July 2023 15:04:24
    1. Create: Description #3326923
      Value: Type of heating boiler: gas, max. thermal power: 20 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3326924
      Value: Gas, condensing
    3. Create: Burner #3326925
      Value: Gas
    4. Create: Number of circuits #3326926
      Value: Double-circuit
    5. Create: Thermal power #3326927
      Value: 6.80 - 20 kW
    6. Create: Thermal load #3326928
      Value: 7 - 20.50 kW
    7. Create: The combustion chamber #3326929
      Value: Closed
    8. Create: Control #3326930
      Value: Electronic
    9. Create: Installation #3326931
      Value: Wall-mounted
    10. Create: Mains voltage #3326932
      Value: Single-phase
    11. Create: Peculiarities #3326933
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    12. Create: Expansion tank volume #3326934
      Value: 8 l
    13. Create: Equipment #3326935
      Value: Display, room thermostat
    14. Create: Fuel #3326936
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3326937
      Value: 2.61 cu. m/hour
    16. Create: LPG consumption #3326938
      Value: 1.92 kg/hour
    17. Create: Nominal pressure of natural gas #3326939
      Value: 20 mbar
    18. Create: Permissible LPG pressure #3326940
      Value: 37 mbar
    19. Create: Heat carrier temperature #3326941
      Value: 25 - 80 °C
    20. Create: Temperature in the DHW circuit #3326942
      Value: 35 - 60 °С
    21. Create: Hot water capacity at t 25°C #3326943
      Value: 13.8 l/min
    22. Create: Hot water capacity at t 35°C #3326944
      Value: 9.8 l/min
    23. Create: Max. water pressure in the DHW circuit #3326945
      Value: 8 bar
    24. Create: Max. water pressure in the heating circuit #3326946
      Value: 3 bar
    25. Create: Gas connection #3326947
      Value: 3/4"
    26. Create: Heating circuit connection #3326948
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3326949
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3326950
      Value: 60/100 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3326951
      Value: Yes
    30. Create: Dimensions WxHxD #3326952
      Value: 600x950x466mm
    31. Create: Weight #3326953
      Value: 65 kg
    32. Create: Image #6304777
      URL: https://avatars.mds.yandex.net/get-mpic/4080064/img_id4710339527230825175.jpeg/orig
    33. Create: Preview image #6304778
      URL: https://avatars.mds.yandex.net/get-mpic/4080064/img_id4710339527230825175.jpeg/orig
  2. Donny Darko 30 April 2023 08:03:55
    Name: Gas boiler BAXI NUVOLA-3 Comfort HT 240; Catalog: Heating boilers