Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 14:58:22
Create:
Description #3324838
Value: Type of heating boiler: gas, max. thermal power: 28 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3324839
Value: Gas, condensing
Create:
Burner #3324840
Value: Gas
Create:
Number of circuits #3324841
Value: Double-circuit
Create:
Thermal power #3324842
Value: 4.70 - 28 kW
Create:
Thermal load #3324843
Value: 5.70 - 28.90 kW
Create:
The combustion chamber #3324844
Value: Closed
Create:
Efficiency #3324845
Value: 105.8 %
Create:
Control #3324846
Value: Electronic
Create:
Installation #3324847
Value: Wall-mounted
Create:
Primary heat exchanger material #3324848
Value: Stainless steel
Create:
Mains voltage #3324849
Value: Single-phase
Create:
Peculiarities #3324850
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
Expansion tank volume #3324851
Value: 10 l
Create:
Equipment #3324852
Value: Display
Create:
Fuel #3324853
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3324854
Value: 3.6 cu. m/hour
Create:
LPG consumption #3324855
Value: 2.64 kg/h
Create:
Nominal pressure of natural gas #3324856
Value: 13 - 20 mbar
Create:
Permissible LPG pressure #3324857
Value: 37 mbar
Create:
Heat carrier temperature #3324858
Value: 25 - 80 °C
Create:
Temperature in the DHW circuit #3324859
Value: 35 - 60 °С
Create:
Hot water capacity at t 25°C #3324860
Value: 18.9 l/min
Create:
Hot water capacity at t 35°C #3324861
Value: 13.5 l/min
Create:
Max. water pressure in the DHW circuit #3324862
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3324863
Value: 3 bar
Create:
Gas connection #3324864
Value: 3/4"
Create:
Heating circuit connection #3324865
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3324866
Value: 1/2"
Create:
Coaxial chimney diameter #3324867
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3324868
Value: Yes
Create:
Dimensions WxHxD #3324869
Value: 450x763x345 mm
Create:
Weight #3324870
Value: 39.5 kg
Create:
Image #6304253
URL: https://avatars.mds.yandex.net/get-mpic/4977172/img_id4045338088767199005.jpeg/orig
Create:
Image #6304254
URL: https://avatars.mds.yandex.net/get-mpic/5234464/img_id2088492486935228989.jpeg/orig
Create:
Image #6304255
URL: https://avatars.mds.yandex.net/get-mpic/1883514/img_id4355027253162367441.jpeg/orig
Create:
Image #6304256
URL: https://avatars.mds.yandex.net/get-mpic/1767083/img_id5651917219289353503.png/orig
Create:
Preview image #6304257
URL: https://avatars.mds.yandex.net/get-mpic/4977172/img_id4045338088767199005.jpeg/orig
Donny Darko 30 April 2023 08:03:30
Name: Gas boiler BAXI LUNA Duo-tec + 33; Catalog: Heating boilers