Change history for item: Gas boiler BAXI MAIN 5 18 F

  1. Donny Darko 07 July 2023 14:57:30
    1. Create: Description #3324486
      Value: Type of heating boiler: gas, max. thermal power: 18 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3324487
      Value: Gas, convection
    3. Create: Burner #3324488
      Value: Gas
    4. Create: Number of circuits #3324489
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3324490
      Value: 9.30 - 18 kW
    6. Create: Thermal load #3324491
      Value: 10.60 - 19.40 kW
    7. Create: The combustion chamber #3324492
      Value: Closed
    8. Create: Efficiency #3324493
      Value: 92.8 %
    9. Create: Control #3324494
      Value: Electronic
    10. Create: Installation #3324495
      Value: Wall-mounted
    11. Create: Mains voltage #3324496
      Value: Single-phase
    12. Create: Peculiarities #3324497
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    13. Create: Expansion tank volume #3324498
      Value: 6 l
    14. Create: Equipment #3324499
      Value: Display
    15. Create: Fuel #3324500
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3324501
      Value: 2.05 cu. m/hour
    17. Create: LPG consumption #3324502
      Value: 1.51 kg/h
    18. Create: Nominal pressure of natural gas #3324503
      Value: 13 - 20 mbar
    19. Create: Permissible LPG pressure #3324504
      Value: 37 mbar
    20. Create: Heat carrier temperature #3324505
      Value: 30 - 76 °С
    21. Create: Temperature in the DHW circuit #3324506
      Value: 35 - 55 °С
    22. Create: Hot water capacity at t 25°C #3324507
      Value: 10.3 l/min
    23. Create: Hot water capacity at t 35°C #3324508
      Value: 7.4 l/min
    24. Create: Max. water pressure in the DHW circuit #3324509
      Value: 8 bar
    25. Create: Max. water pressure in the heating circuit #3324510
      Value: 3 bar
    26. Create: Coaxial chimney diameter #3324511
      Value: 60/100 mm
    27. Create: Dimensions WxHxD #3324512
      Value: 400x700x298 mm
    28. Create: Weight #3324513
      Value: 27 kg
    29. Create: Additional Information #3324514
      Value: Efficiency at 30% load - 90.3%
    30. Create: Image #6304193
      URL: https://avatars.mds.yandex.net/get-mpic/4580925/img_id1454437895926336273.jpeg/orig
    31. Create: Preview image #6304194
      URL: https://avatars.mds.yandex.net/get-mpic/4580925/img_id1454437895926336273.jpeg/orig
  2. Donny Darko 30 April 2023 08:03:27
    Name: Gas boiler BAXI MAIN 5 18 F; Catalog: Heating boilers