Change history for item: Gas boiler BAXI MAIN Four 240 F

  1. Donny Darko 07 July 2023 14:57:17
    1. Create: Description #3324393
      Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3324394
      Value: Gas, convection
    3. Create: Burner #3324395
      Value: Gas
    4. Create: Number of circuits #3324396
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3324397
      Value: 9.30 - 24 kW
    6. Create: Thermal load #3324398
      Value: 10.60 - 25.80 kW
    7. Create: The combustion chamber #3324399
      Value: Closed
    8. Create: Efficiency #3324400
      Value: 92.9 %
    9. Create: Control #3324401
      Value: Electronic
    10. Create: Installation #3324402
      Value: Wall-mounted
    11. Create: Mains voltage #3324403
      Value: Single-phase
    12. Create: Peculiarities #3324404
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    13. Create: Expansion tank volume #3324405
      Value: 6 l
    14. Create: Equipment #3324406
      Value: Display
    15. Create: Fuel #3324407
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3324408
      Value: 2.73 cu. m/hour
    17. Create: LPG consumption #3324409
      Value: 2 kg/hour
    18. Create: Nominal pressure of natural gas #3324410
      Value: 13 - 20 mbar
    19. Create: Permissible LPG pressure #3324411
      Value: 37 mbar
    20. Create: Heat carrier temperature #3324412
      Value: 30 - 76 °С
    21. Create: Temperature in the DHW circuit #3324413
      Value: 35 - 55 °С
    22. Create: Hot water capacity at t 25°C #3324414
      Value: 13.7 l/min
    23. Create: Hot water capacity at t 35°C #3324415
      Value: 9.8 l/min
    24. Create: Max. water pressure in the DHW circuit #3324416
      Value: 8 bar
    25. Create: Max. water pressure in the heating circuit #3324417
      Value: 3 bar
    26. Create: Gas connection #3324418
      Value: 3/4"
    27. Create: Heating circuit connection #3324419
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3324420
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3324421
      Value: 60/100 mm
    30. Create: Dimensions WxHxD #3324422
      Value: 400x730x299 mm
    31. Create: Weight #3324423
      Value: 31 kg
    32. Create: Additional Information #3324424
      Value: Maximum efficiency at 30% load - 87.7%
    33. Create: Image #6304181
      URL: https://avatars.mds.yandex.net/get-mpic/4377400/img_id7174107059084885884.jpeg/orig
    34. Create: Preview image #6304182
      URL: https://avatars.mds.yandex.net/get-mpic/4377400/img_id7174107059084885884.jpeg/orig
  2. Donny Darko 30 April 2023 08:03:26
    Name: Gas boiler BAXI MAIN Four 240 F; Catalog: Heating boilers