Donny Darko 07 July 2023 14:57:12
Create:
Description #3324362
Value: Type of heating boiler: gas, max. thermal power: 18 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3324363
Value: Gas, convection
Create:
Burner #3324364
Value: Gas
Create:
Number of circuits #3324365
Value: Double-circuit, bithermic heat exchanger
Create:
Thermal power #3324366
Value: 9.30 - 18 kW
Create:
Thermal load #3324367
Value: 10.60 - 19.40 kW
Create:
The combustion chamber #3324368
Value: Closed
Create:
Efficiency #3324369
Value: 92.9 %
Create:
Control #3324370
Value: Electronic
Create:
Installation #3324371
Value: Wall-mounted
Create:
Mains voltage #3324372
Value: Single-phase
Create:
Peculiarities #3324373
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
Expansion tank volume #3324374
Value: 6 l
Create:
Equipment #3324375
Value: Display
Create:
Fuel #3324376
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3324377
Value: 2.05 cu. m/hour
Create:
LPG consumption #3324378
Value: 1.5 kg/hour
Create:
Nominal pressure of natural gas #3324379
Value: 13 - 20 mbar
Create:
Permissible LPG pressure #3324380
Value: 37 mbar
Create:
Heat carrier temperature #3324381
Value: 30 - 80 °С
Create:
Temperature in the DHW circuit #3324382
Value: 35 - 55 °С
Create:
Hot water capacity at t 25°C #3324383
Value: 10.3 l/min
Create:
Hot water capacity at t 35°C #3324384
Value: 7.4 l/min
Create:
Max. water pressure in the DHW circuit #3324385
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3324386
Value: 3 bar
Create:
Gas connection #3324387
Value: 3/4"
Create:
Heating circuit connection #3324388
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3324389
Value: 1/2"
Create:
Coaxial chimney diameter #3324390
Value: 60/100 mm
Create:
Dimensions WxHxD #3324391
Value: 400x730x299 mm
Create:
Weight #3324392
Value: 31 kg
Create:
Image #6304179
URL: https://avatars.mds.yandex.net/get-mpic/4585707/img_id5029668939581254497.jpeg/orig
Create:
Preview image #6304180
URL: https://avatars.mds.yandex.net/get-mpic/4585707/img_id5029668939581254497.jpeg/orig
Donny Darko 30 April 2023 08:03:26
Name: Gas boiler BAXI MAIN Four 18 F; Catalog: Heating boilers