Donny Darko 07 July 2023 14:56:15
Create:
Description #3323937
Value: Type of heating boiler: gas, max. thermal power: 31 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3323938
Value: Gas, convection
Create:
Burner #3323939
Value: Gas
Create:
Number of circuits #3323940
Value: Double-circuit
Create:
Thermal power #3323941
Value: 10.60 - 31 kW
Create:
Thermal load #3323942
Value: 11.90 - 33.10 kW
Create:
The combustion chamber #3323943
Value: Closed
Create:
Efficiency #3323944
Value: 91.3 %
Create:
Control #3323945
Value: Electronic
Create:
Installation #3323946
Value: Wall-mounted
Create:
Primary heat exchanger material #3323947
Value: Copper
Create:
Mains voltage #3323948
Value: Single-phase
Create:
Peculiarities #3323949
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3323950
Value: 10 l
Create:
Equipment #3323951
Value: Display, room thermostat, remote control
Create:
Fuel #3323952
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3323953
Value: 3.52 cu. m/hour
Create:
LPG consumption #3323954
Value: 2.63 kg/h
Create:
Nominal pressure of natural gas #3323955
Value: 13 - 20 mbar
Create:
Permissible LPG pressure #3323956
Value: 37 mbar
Create:
Heat carrier temperature #3323957
Value: 30 - 85 °С
Create:
Temperature in the DHW circuit #3323958
Value: 35 - 65 °С
Create:
Hot water capacity at t 25°C #3323959
Value: 17.8 l/min
Create:
Hot water capacity at t 35°C #3323960
Value: 12.6 l/min
Create:
Max. water pressure in the DHW circuit #3323961
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3323962
Value: 3 bar
Create:
Gas connection #3323963
Value: 3/4"
Create:
Heating circuit connection #3323964
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3323965
Value: 1/2"
Create:
Coaxial chimney diameter #3323966
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3323967
Value: Yes
Create:
Dimensions WxHxD #3323968
Value: 450x763x345 mm
Create:
Weight #3323969
Value: 40 kg
Create:
Additional Information #3323970
Value: Removable digital display with Wi-Fi control
Create:
Image #6303978
URL: https://avatars.mds.yandex.net/get-mpic/4544069/img_id4845682795327105640.jpeg/orig
Create:
Preview image #6303979
URL: https://avatars.mds.yandex.net/get-mpic/4544069/img_id4845682795327105640.jpeg/orig
Donny Darko 30 April 2023 08:03:22
Name: Gas boiler BAXI LUNA-3 COMFORT AIR 310 Fi; Catalog: Heating boilers