Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 14:55:48
Create:
Description #3323734
Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
Create:
Type of heating boiler #3323735
Value: Gas, convection
Create:
Burner #3323736
Value: Gas
Create:
Number of circuits #3323737
Value: Double-circuit
Create:
Thermal power #3323738
Value: 9.30 - 24 kW
Create:
Thermal load #3323739
Value: 10.60 - 26.30 kW
Create:
The combustion chamber #3323740
Value: Open
Create:
Heated area #3323741
Value: 260 sq.m
Create:
Efficiency #3323742
Value: 91.2 %
Create:
Control #3323743
Value: Electronic
Create:
Installation #3323744
Value: Wall-mounted
Create:
Primary heat exchanger material #3323745
Value: Copper
Create:
Mains voltage #3323746
Value: Single-phase
Create:
Peculiarities #3323747
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
Expansion tank volume #3323748
Value: 8 l
Create:
Equipment #3323749
Value: Display
Create:
Fuel #3323750
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3323751
Value: 2.78 cu. m/hour
Create:
LPG consumption #3323752
Value: 2.07 kg/h
Create:
Nominal pressure of natural gas #3323753
Value: 13 - 20 mbar
Create:
Permissible LPG pressure #3323754
Value: 37 mbar
Create:
Heat carrier temperature #3323755
Value: 30 - 85 °С
Create:
Temperature in the DHW circuit #3323756
Value: 35 - 65 °С
Create:
Hot water capacity at t 20°C #3323757
Value: 18.8 l/min
Create:
Hot water capacity at t 25°C #3323758
Value: 13.7 l/min
Create:
Hot water capacity at t 30°C #3323759
Value: 12.5 l/min
Create:
Hot water capacity at t 35°C #3323760
Value: 9.8 l/min
Create:
Hot water capacity at t 50°C #3323761
Value: 7.5 l/min
Create:
Max. water pressure in the DHW circuit #3323762
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3323763
Value: 3 bar
Create:
Gas connection #3323764
Value: 3/4"
Create:
Heating circuit connection #3323765
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3323766
Value: 1/2"
Create:
Chimney diameter #3323767
Value: 120 mm
Create:
Dimensions WxHxD #3323768
Value: 450x763x345 mm
Create:
Weight #3323769
Value: 33 kg
Create:
Additional Information #3323770
Value: Warranty 2 years
Create:
Image #6303873
URL: https://avatars.mds.yandex.net/get-mpic/3689399/img_id2353300835269750298.jpeg/orig
Create:
Image #6303874
URL: https://avatars.mds.yandex.net/get-mpic/4250892/img_id926801033791784835.jpeg/orig
Create:
Image #6303875
URL: https://avatars.mds.yandex.net/get-mpic/1911047/img_id8218885566371237285.jpeg/orig
Create:
Image #6303876
URL: https://avatars.mds.yandex.net/get-mpic/5165418/img_id8259059915406165126.jpeg/orig
Create:
Image #6303877
URL: https://avatars.mds.yandex.net/get-mpic/4012371/img_id6853979846135651878.jpeg/orig
Create:
Image #6303878
URL: https://avatars.mds.yandex.net/get-mpic/3614670/img_id1045871695275679643.jpeg/orig
Create:
Image #6303879
URL: https://avatars.mds.yandex.net/get-mpic/1865974/img_id6114199470674501041.jpeg/orig
Create:
Image #6303880
URL: https://avatars.mds.yandex.net/get-mpic/4343007/img_id37875623993552061.jpeg/orig
Create:
Image #6303881
URL: https://avatars.mds.yandex.net/get-mpic/4407413/img_id5707864747475829991.jpeg/orig
Create:
Image #6303882
URL: https://avatars.mds.yandex.net/get-mpic/5254518/img_id5942426877147404523.jpeg/orig
Create:
Image #6303883
URL: https://avatars.mds.yandex.net/get-mpic/1861069/img_id7580998712227097950.jpeg/orig
Create:
Preview image #6303884
URL: https://avatars.mds.yandex.net/get-mpic/3689399/img_id2353300835269750298.jpeg/orig
Donny Darko 30 April 2023 08:03:20
Name: Gas boiler BAXI LUNA-3 240 i; Catalog: Heating boilers