Change history for item: Gas Beretta Fabula 38 CAI 120

  1. Donny Darko 07 July 2023 14:51:26
    1. Create: Description #3322260
      Value: Type of heating boiler: gas, max. heating power: 37.80 kW, number of circuits: double-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of supply: single-phase,
    2. Create: Type of heating boiler #3322261
      Value: Gas, convection
    3. Create: Burner #3322262
      Value: Gas
    4. Create: Number of circuits #3322263
      Value: Double-circuit
    5. Create: Max. thermal power #3322264
      Value: 37.80 kW
    6. Create: Max. thermal load #3322265
      Value: 42 kW
    7. Create: The combustion chamber #3322266
      Value: Open
    8. Create: Efficiency #3322267
      Value: 90 %
    9. Create: Control #3322268
      Value: Electronic
    10. Create: Installation #3322269
      Value: Floor
    11. Create: Primary heat exchanger material #3322270
      Value: Cast iron
    12. Create: Mains voltage #3322271
      Value: Single-phase
    13. Create: Peculiarities #3322272
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: The volume of the built-in boiler #3322273
      Value: 120 l
    15. Create: Expansion tank volume #3322274
      Value: 16 l
    16. Create: Equipment #3322275
      Value: Built-in boiler, display
    17. Create: Fuel #3322276
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3322277
      Value: 4.3 cu. m/hour
    19. Create: LPG consumption #3322278
      Value: 3.29 kg/h
    20. Create: Nominal pressure of natural gas #3322279
      Value: 20 mbar
    21. Create: Permissible LPG pressure #3322280
      Value: 37 mbar
    22. Create: Heat carrier temperature #3322281
      Value: 33 - 82 °С
    23. Create: Max. temperature in the DHW circuit #3322282
      Value: 70 °С
    24. Create: Hot water capacity at t 25°C #3322283
      Value: 900 l/min
    25. Create: Hot water capacity at t 30°C #3322284
      Value: 650 l/min
    26. Create: Max. water pressure in the DHW circuit #3322285
      Value: 6 bar
    27. Create: Max. water pressure in the heating circuit #3322286
      Value: 3 bar
    28. Create: Gas connection #3322287
      Value: 1"
    29. Create: Heating circuit connection #3322288
      Value: 3/4"
    30. Create: Branch pipe for connecting the DHW circuit #3322289
      Value: 3/4"
    31. Create: Chimney diameter #3322290
      Value: 136 mm
    32. Create: Dimensions WxHxD #3322291
      Value: 600x1475x770mm
    33. Create: Weight #3322292
      Value: 136 kg
    34. Create: Additional Information #3322293
      Value: Monitoring the health of the smoke exhaust system, heating expansion tank 12 l, DHW expansion tank 4 l
    35. Create: Image #6303613
      URL: https://avatars.mds.yandex.net/get-mpic/1750207/img_id8818021938010852573/orig
    36. Create: Preview image #6303614
      URL: https://avatars.mds.yandex.net/get-mpic/1750207/img_id8818021938010852573/orig
  2. Donny Darko 30 April 2023 08:03:03
    Name: Gas Beretta Fabula 38 CAI 120; Catalog: Heating boilers