Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 14:51:16
Create:
Description #3322192
Value: Type of heating boiler: gas, max. thermal power: 31 kW, number of circuits: double-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
Create:
Type of heating boiler #3322193
Value: Gas, convection
Create:
Burner #3322194
Value: Gas
Create:
Number of circuits #3322195
Value: Double-circuit
Create:
Max. thermal power #3322196
Value: 31 kW
Create:
Max. thermal load #3322197
Value: 34.40 kW
Create:
The combustion chamber #3322198
Value: Open
Create:
Efficiency #3322199
Value: 90.12 %
Create:
Control #3322200
Value: Electronic
Create:
Installation #3322201
Value: Floor
Create:
Primary heat exchanger material #3322202
Value: Cast iron
Create:
Mains voltage #3322203
Value: Single-phase
Create:
Peculiarities #3322204
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
The volume of the built-in boiler #3322205
Value: 80 l
Create:
Expansion tank volume #3322206
Value: 15 l
Create:
Equipment #3322207
Value: Built-in boiler, display
Create:
Fuel #3322208
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3322209
Value: 3.5 cu. m/hour
Create:
LPG consumption #3322210
Value: 2.7 kg/hour
Create:
Nominal pressure of natural gas #3322211
Value: 20 mbar
Create:
Permissible LPG pressure #3322212
Value: 37 mbar
Create:
Heat carrier temperature #3322213
Value: 33 - 82 °С
Create:
Max. temperature in the DHW circuit #3322214
Value: 70 °С
Create:
Hot water capacity at t 25°C #3322215
Value: 1049 l/min
Create:
Hot water capacity at t 30°C #3322216
Value: 749 l/min
Create:
Max. water pressure in the DHW circuit #3322217
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3322218
Value: 3 bar
Create:
Gas connection #3322219
Value: 1"
Create:
Heating circuit connection #3322220
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3322221
Value: 3/4"
Create:
Chimney diameter #3322222
Value: 142 mm
Create:
Dimensions WxHxD #3322223
Value: 450x1350x780 mm
Create:
Weight #3322224
Value: 126 kg
Create:
Additional Information #3322225
Value: Monitoring the health of the smoke exhaust system, heating expansion tank 12 l, DHW expansion tank 3 l
Create:
Image #6303609
URL: https://avatars.mds.yandex.net/get-mpic/1750207/img_id8818021938010852573/orig
Create:
Preview image #6303610
URL: https://avatars.mds.yandex.net/get-mpic/1750207/img_id8818021938010852573/orig
Donny Darko 30 April 2023 08:03:03
Name: Gas Beretta Fabula 31 CAI 80; Catalog: Heating boilers