Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 14:51:11
Create:
Description #3322159
Value: Type of heating boiler: gas, max. heating power: 25.80 kW, number of circuits: double-circuit, location: floor, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
Create:
Type of heating boiler #3322160
Value: Gas, convection
Create:
Burner #3322161
Value: Gas
Create:
Number of circuits #3322162
Value: Double-circuit
Create:
Max. thermal power #3322163
Value: 25.80 kW
Create:
Max. thermal load #3322164
Value: 28.50 kW
Create:
The combustion chamber #3322165
Value: Closed
Create:
Efficiency #3322166
Value: 90.53 %
Create:
Control #3322167
Value: Electronic
Create:
Installation #3322168
Value: Floor
Create:
Primary heat exchanger material #3322169
Value: Cast iron
Create:
Mains voltage #3322170
Value: Single-phase
Create:
Peculiarities #3322171
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
The volume of the built-in boiler #3322172
Value: 80 l
Create:
Expansion tank volume #3322173
Value: 13.4 l
Create:
Equipment #3322174
Value: Built-in boiler, display
Create:
Fuel #3322175
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3322176
Value: 2.99 cu. m/hour
Create:
LPG consumption #3322177
Value: 2.23 kg/h
Create:
Nominal pressure of natural gas #3322178
Value: 20 mbar
Create:
Permissible LPG pressure #3322179
Value: 37 mbar
Create:
Heat carrier temperature #3322180
Value: 33 - 82 °С
Create:
Max. temperature in the DHW circuit #3322181
Value: 70 °С
Create:
Hot water capacity at t 25°C #3322182
Value: 1049 l/min
Create:
Hot water capacity at t 30°C #3322183
Value: 750 l/min
Create:
Max. water pressure in the DHW circuit #3322184
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3322185
Value: 3 bar
Create:
Gas connection #3322186
Value: 1"
Create:
Heating circuit connection #3322187
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3322188
Value: 3/4"
Create:
Dimensions WxHxD #3322189
Value: 450x1350x780 mm
Create:
Weight #3322190
Value: 150 kg
Create:
Additional Information #3322191
Value: Monitoring the health of the smoke exhaust system, heating expansion tank 10.4 l, expansion tank 3 l
Create:
Image #6303607
URL: https://avatars.mds.yandex.net/get-mpic/1750207/img_id8818021938010852573/orig
Create:
Preview image #6303608
URL: https://avatars.mds.yandex.net/get-mpic/1750207/img_id8818021938010852573/orig
Donny Darko 30 April 2023 08:03:02
Name: Gas Beretta Fabula 32 CSI 80; Catalog: Heating boilers