Value: Type of heating boiler: gas, max. heating power: 28.80 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of supply: single-phase,
Create:
Type of heating boiler #3320825
Value: Gas, convection
Create:
Burner #3320826
Value: Gas
Create:
Number of circuits #3320827
Value: Double-circuit
Create:
Thermal power #3320828
Value: 8.80 - 28.80 kW
Create:
Thermal load #3320829
Value: 10.70 - 31.90 kW
Create:
The combustion chamber #3320830
Value: Open
Create:
Efficiency #3320831
Value: 88.4 %
Create:
Control #3320832
Value: Electronic
Create:
Installation #3320833
Value: Wall-mounted
Create:
Mains voltage #3320834
Value: Single-phase
Create:
Peculiarities #3320835
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
The volume of the built-in boiler #3320836
Value: 60 l
Create:
Expansion tank volume #3320837
Value: 10 l
Create:
Equipment #3320838
Value: Built-in boiler
Create:
Fuel #3320839
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3320840
Value: 3.37 cu. m/hour
Create:
LPG consumption #3320841
Value: 2.51 kg/h
Create:
Nominal pressure of natural gas #3320842
Value: 13.50 - 20 mbar
Create:
Permissible LPG pressure #3320843
Value: 37 mbar
Create:
Heat carrier temperature #3320844
Value: 40 - 80 °С
Create:
Temperature in the DHW circuit #3320845
Value: 40 - 63 °С
Create:
Hot water capacity at t 25°C #3320846
Value: 16.5 l/min
Create:
Hot water capacity at t 30°C #3320847
Value: 13.8 l/min
Create:
Hot water capacity at t 35°C #3320848
Value: 11.8 l/min
Create:
Max. water pressure in the DHW circuit #3320849
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3320850
Value: 3 bar
Create:
Gas connection #3320851
Value: 3/4"
Create:
Heating circuit connection #3320852
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3320853
Value: 1/2"
Create:
Chimney diameter #3320854
Value: 140 mm
Create:
Dimensions WxHxD #3320855
Value: 600x940x465 mm
Create:
Weight #3320856
Value: 58.5 kg
Create:
Image #6303488
URL: https://avatars.mds.yandex.net/get-mpic/1865271/img_id841423903577460431/orig
Create:
Preview image #6303489
URL: https://avatars.mds.yandex.net/get-mpic/1865271/img_id841423903577460431/orig
Donny Darko 30 April 2023 08:02:48
Name: Gas Beretta Boiler 28 BAI 28.8 kW double-circuit; Catalog: Heating boilers