Change history for item: Gas Beretta Exclusive MIX 35 CSI 33.2 kW double-circuit

  1. Donny Darko 07 July 2023 14:46:50
    1. Create: Description #3320769
      Value: Type of heating boiler: gas, max. thermal power: 33.20 kW, number of circuits: double-circuit, location: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3320770
      Value: Gas, convection
    3. Create: Burner #3320771
      Value: Gas
    4. Create: Number of circuits #3320772
      Value: Double-circuit
    5. Create: Thermal power #3320773
      Value: 8.86 - 33.20 kW
    6. Create: The combustion chamber #3320774
      Value: Closed
    7. Create: Efficiency #3320775
      Value: 93.4 %
    8. Create: Control #3320776
      Value: Electronic
    9. Create: Installation #3320777
      Value: Wall-mounted
    10. Create: Mains voltage #3320778
      Value: Single-phase
    11. Create: Peculiarities #3320779
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, gas filter
    12. Create: Expansion tank volume #3320780
      Value: 10 l
    13. Create: Equipment #3320781
      Value: Display
    14. Create: Fuel #3320782
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3320783
      Value: 4 cu. m/hour
    16. Create: LPG consumption #3320784
      Value: 2.94 kg/h
    17. Create: Nominal pressure of natural gas #3320785
      Value: 13.50 mbar
    18. Create: Permissible LPG pressure #3320786
      Value: 37 mbar
    19. Create: Heat carrier temperature #3320787
      Value: 40 - 80 °С
    20. Create: Temperature in the DHW circuit #3320788
      Value: 35 - 60 °С
    21. Create: Hot water capacity at t 25°C #3320789
      Value: 20.2 l/min
    22. Create: Hot water capacity at t 30°C #3320790
      Value: 16.9 l/min
    23. Create: Max. water pressure in the DHW circuit #3320791
      Value: 6 bar
    24. Create: Max. water pressure in the heating circuit #3320792
      Value: 3 bar
    25. Create: Gas connection #3320793
      Value: 3/4"
    26. Create: Heating circuit connection #3320794
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3320795
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3320796
      Value: 60/100 mm
    29. Create: Dimensions WxHxD #3320797
      Value: 450x773x332mm
    30. Create: Weight #3320798
      Value: 44 kg
    31. Create: Image #6303484
      URL: https://avatars.mds.yandex.net/get-mpic/4219828/img_id7776200859682337390.jpeg/orig
    32. Create: Preview image #6303485
      URL: https://avatars.mds.yandex.net/get-mpic/4219828/img_id7776200859682337390.jpeg/orig
  2. Donny Darko 30 April 2023 08:02:47
    Name: Gas Beretta Exclusive MIX 35 CSI 33.2 kW double-circuit; Catalog: Heating boilers