Change history for item: Gas Beretta City 35 CSI 37.6 kW double-circuit

  1. Donny Darko 07 July 2023 14:46:18
    1. Create: Description #3320569
      Value: Type of heating boiler: gas, max. heating power: 37.60 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3320570
      Value: Gas, convection
    3. Create: Burner #3320571
      Value: Gas
    4. Create: Number of circuits #3320572
      Value: Double-circuit
    5. Create: Thermal power #3320573
      Value: 11.09 - 37.60 kW
    6. Create: The combustion chamber #3320574
      Value: Closed
    7. Create: Efficiency #3320575
      Value: 92.9 %
    8. Create: Control #3320576
      Value: Electronic
    9. Create: Installation #3320577
      Value: Wall-mounted
    10. Create: Mains voltage #3320578
      Value: Single-phase
    11. Create: Peculiarities #3320579
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    12. Create: Expansion tank volume #3320580
      Value: 10 l
    13. Create: Equipment #3320581
      Value: Display
    14. Create: Fuel #3320582
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3320583
      Value: 3.98 cu. m/hour
    16. Create: LPG consumption #3320584
      Value: 2.92 kg/hour
    17. Create: Nominal pressure of natural gas #3320585
      Value: 13.50 - 20 mbar
    18. Create: Permissible LPG pressure #3320586
      Value: 37 mbar
    19. Create: Heat carrier temperature #3320587
      Value: 40 - 80 °С
    20. Create: Temperature in the DHW circuit #3320588
      Value: 37 - 60 °С
    21. Create: Hot water capacity at t 25°C #3320589
      Value: 20 l/min
    22. Create: Hot water capacity at t 30°C #3320590
      Value: 16.7 l/min
    23. Create: Hot water capacity at t 35°C #3320591
      Value: 14.3 l/min
    24. Create: Max. water pressure in the DHW circuit #3320592
      Value: 6 bar
    25. Create: Gas connection #3320593
      Value: 3/4"
    26. Create: Heating circuit connection #3320594
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3320595
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3320596
      Value: 60/100 mm and 80/125 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3320597
      Value: Yes
    30. Create: Dimensions WxHxD #3320598
      Value: 505x780x328mm
    31. Create: Weight #3320599
      Value: 42 kg
    32. Create: Image #6303469
      URL: https://avatars.mds.yandex.net/get-mpic/1707869/img_id8707855427224065666/orig
    33. Create: Image #6303470
      URL: https://avatars.mds.yandex.net/get-mpic/4407413/img_id8176874070146015165.jpeg/orig
    34. Create: Preview image #6303471
      URL: https://avatars.mds.yandex.net/get-mpic/1707869/img_id8707855427224065666/orig
  2. Donny Darko 30 April 2023 08:02:45
    Name: Gas Beretta City 35 CSI 37.6 kW double-circuit; Catalog: Heating boilers