Change history for item: Gas Haier L1P26-F21ST HEC 23.9kW double-circuit

  1. Donny Darko 07 July 2023 14:45:29
    1. Create: Description #3320283
      Value: Type of heating boiler: gas, max. heating power: 23.90 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3320284
      Value: Gas, convection
    3. Create: Burner #3320285
      Value: Gas
    4. Create: Number of circuits #3320286
      Value: Double-circuit
    5. Create: Thermal power #3320287
      Value: 8 - 23.90 kW
    6. Create: Max. thermal load #3320288
      Value: 26 kW
    7. Create: The combustion chamber #3320289
      Value: Closed
    8. Create: Heated area #3320290
      Value: 200 sq.m
    9. Create: Efficiency #3320291
      Value: 92 %
    10. Create: Control #3320292
      Value: Electronic
    11. Create: Installation #3320293
      Value: Wall-mounted
    12. Create: Primary heat exchanger material #3320294
      Value: Copper
    13. Create: Secondary heat exchanger material #3320295
      Value: Stainless steel
    14. Create: Mains voltage #3320296
      Value: Single-phase
    15. Create: Peculiarities #3320297
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    16. Create: Expansion tank volume #3320298
      Value: 6 l
    17. Create: Equipment #3320299
      Value: Display
    18. Create: Fuel #3320300
      Value: Natural gas, liquefied gas
    19. Create: Natural gas consumption #3320301
      Value: 2.81 cu. m/hour
    20. Create: Nominal pressure of natural gas #3320302
      Value: 13 - 20 mbar
    21. Create: Permissible LPG pressure #3320303
      Value: 50 mbar
    22. Create: Heat carrier temperature #3320304
      Value: 30 - 85 °С
    23. Create: Temperature in the DHW circuit #3320305
      Value: 30 - 60 °С
    24. Create: Hot water capacity at t 30°C #3320306
      Value: 10.5 l/min
    25. Create: Max. water pressure in the DHW circuit #3320307
      Value: 6 bar
    26. Create: Gas connection #3320308
      Value: 3/4"
    27. Create: Heating circuit connection #3320309
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3320310
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3320311
      Value: 60/100 mm
    30. Create: Dimensions WxHxD #3320312
      Value: 403x750x320 mm
    31. Create: Weight #3320313
      Value: 35 kg
    32. Create: Image #6303415
      URL: https://avatars.mds.yandex.net/get-mpic/4342845/img_id6056918445376275807.jpeg/orig
    33. Create: Preview image #6303416
      URL: https://avatars.mds.yandex.net/get-mpic/4342845/img_id6056918445376275807.jpeg/orig
  2. Donny Darko 30 April 2023 08:02:42
    Name: Gas Haier L1P26-F21ST HEC 23.9kW double-circuit; Catalog: Heating boilers