Change history for item: Gas Haier Asio L1P26-F21S

  1. Donny Darko 07 July 2023 14:45:15
    1. Create: Description #3320191
      Value: Type of heating boiler: gas, max. heating power: 23.90 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3320192
      Value: Gas, convection
    3. Create: Burner #3320193
      Value: Gas
    4. Create: Number of circuits #3320194
      Value: Double-circuit
    5. Create: Thermal power #3320195
      Value: 9 - 23.90 kW
    6. Create: Max. thermal load #3320196
      Value: 26 kW
    7. Create: The combustion chamber #3320197
      Value: Closed
    8. Create: Heated area #3320198
      Value: 240 sq.m
    9. Create: Efficiency #3320199
      Value: 92 %
    10. Create: Control #3320200
      Value: Electronic
    11. Create: Installation #3320201
      Value: Wall-mounted
    12. Create: Primary heat exchanger material #3320202
      Value: Copper
    13. Create: Secondary heat exchanger material #3320203
      Value: Stainless steel
    14. Create: Mains voltage #3320204
      Value: Single-phase
    15. Create: Peculiarities #3320205
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    16. Create: Expansion tank volume #3320206
      Value: 6 l
    17. Create: Equipment #3320207
      Value: Display, room thermostat
    18. Create: Fuel #3320208
      Value: Natural gas, liquefied gas
    19. Create: Natural gas consumption #3320209
      Value: 2.85 cu. m/hour
    20. Create: Nominal pressure of natural gas #3320210
      Value: 13 - 20 mbar
    21. Create: Permissible LPG pressure #3320211
      Value: 50 mbar
    22. Create: Heat carrier temperature #3320212
      Value: 30 - 85 °С
    23. Create: Temperature in the DHW circuit #3320213
      Value: 30 - 60 °С
    24. Create: Hot water capacity at t 35°C #3320214
      Value: 10.5 l/min
    25. Create: Max. water pressure in the DHW circuit #3320215
      Value: 6 bar
    26. Create: Max. water pressure in the heating circuit #3320216
      Value: 3 bar
    27. Create: Gas connection #3320217
      Value: 3/4"
    28. Create: Heating circuit connection #3320218
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3320219
      Value: 1/2"
    30. Create: Coaxial chimney diameter #3320220
      Value: 60/100 mm
    31. Create: Dimensions WxHxD #3320221
      Value: 403x750x320 mm
    32. Create: Weight #3320222
      Value: 32.5 kg
    33. Create: Image #6303409
      URL: https://avatars.mds.yandex.net/get-mpic/4383514/img_id6393056181193072421.jpeg/orig
    34. Create: Preview image #6303410
      URL: https://avatars.mds.yandex.net/get-mpic/4383514/img_id6393056181193072421.jpeg/orig
  2. Donny Darko 30 April 2023 08:02:41
    Name: Gas Haier Asio L1P26-F21S; Catalog: Heating boilers