Change history for item: Gas Haier Aquila L1P26-F21ST

  1. Donny Darko 07 July 2023 14:44:58
    1. Create: Description #3320083
      Value: Type of heating boiler: gas, max. heating power: 23.90 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3320084
      Value: Gas, convection
    3. Create: Burner #3320085
      Value: Gas
    4. Create: Number of circuits #3320086
      Value: Double-circuit
    5. Create: Thermal power #3320087
      Value: 8 - 23.90 kW
    6. Create: The combustion chamber #3320088
      Value: Closed
    7. Create: Heated area #3320089
      Value: 200 sq.m
    8. Create: Efficiency #3320090
      Value: 92 %
    9. Create: Control #3320091
      Value: Electronic
    10. Create: Installation #3320092
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3320093
      Value: Copper
    12. Create: Mains voltage #3320094
      Value: Single-phase
    13. Create: Peculiarities #3320095
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, connector for external control, thermometer
    14. Create: Expansion tank volume #3320096
      Value: 6 l
    15. Create: Equipment #3320097
      Value: Display, room thermostat
    16. Create: Fuel #3320098
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3320099
      Value: 2.81 cu. m/hour
    18. Create: Nominal pressure of natural gas #3320100
      Value: 13 - 20 mbar
    19. Create: Permissible LPG pressure #3320101
      Value: 50 mbar
    20. Create: Heat carrier temperature #3320102
      Value: 30 - 85 °С
    21. Create: Temperature in the DHW circuit #3320103
      Value: 30 - 60 °С
    22. Create: Hot water capacity at t 30°C #3320104
      Value: 10.5 l/min
    23. Create: Max. water pressure in the DHW circuit #3320105
      Value: 6 bar
    24. Create: Max. water pressure in the heating circuit #3320106
      Value: 3 bar
    25. Create: Gas connection #3320107
      Value: 3/4"
    26. Create: Heating circuit connection #3320108
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3320109
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3320110
      Value: 60/100 mm
    29. Create: Dimensions WxHxD #3320111
      Value: 403x750x320 mm
    30. Create: Weight #3320112
      Value: 35 kg
    31. Create: Image #6303400
      URL: https://avatars.mds.yandex.net/get-mpic/4219828/img_id1149786930861533263.jpeg/orig
    32. Create: Preview image #6303401
      URL: https://avatars.mds.yandex.net/get-mpic/4219828/img_id1149786930861533263.jpeg/orig
  2. Donny Darko 30 April 2023 08:02:39
    Name: Gas Haier Aquila L1P26-F21ST; Catalog: Heating boilers