Change history for item: Gas Haier Falco L1P20-F21T 17.6 kW double-circuit

  1. Donny Darko 07 July 2023 14:44:44
    1. Create: Description #3319996
      Value: Type of heating boiler: gas, max. heating power: 17.60 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3319997
      Value: Gas, convection
    3. Create: Burner #3319998
      Value: Gas
    4. Create: Number of circuits #3319999
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3320000
      Value: 7.04 - 17.60 kW
    6. Create: Max. thermal load #3320001
      Value: 20 kW
    7. Create: The combustion chamber #3320002
      Value: Closed
    8. Create: Heated area #3320003
      Value: 150 sq.m
    9. Create: Efficiency #3320004
      Value: 88 %
    10. Create: Control #3320005
      Value: Electronic
    11. Create: Installation #3320006
      Value: Wall-mounted
    12. Create: Primary heat exchanger material #3320007
      Value: Copper
    13. Create: Mains voltage #3320008
      Value: Single-phase
    14. Create: Peculiarities #3320009
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, thermometer
    15. Create: Expansion tank volume #3320010
      Value: 6 l
    16. Create: Equipment #3320011
      Value: Outdoor temperature sensor, display
    17. Create: Fuel #3320012
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3320013
      Value: 2.19 cu. m/hour
    19. Create: Nominal pressure of natural gas #3320014
      Value: 13 - 20 mbar
    20. Create: Permissible LPG pressure #3320015
      Value: 50 mbar
    21. Create: Max. coolant temperature #3320016
      Value: 90 °С
    22. Create: Temperature in the DHW circuit #3320017
      Value: 30 - 60 °С
    23. Create: Hot water capacity at t 30°C #3320018
      Value: 8.5 l/min
    24. Create: Max. water pressure in the DHW circuit #3320019
      Value: 6 bar
    25. Create: Max. water pressure in the heating circuit #3320020
      Value: 3 bar
    26. Create: Gas connection #3320021
      Value: 3/4"
    27. Create: Heating circuit connection #3320022
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3320023
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3320024
      Value: 60/100 mm
    30. Create: Dimensions WxHxD #3320025
      Value: 403x750x320 mm
    31. Create: Weight #3320026
      Value: 34 kg
    32. Create: Image #6303394
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id3809812373387787769/orig
    33. Create: Preview image #6303395
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id3809812373387787769/orig
  2. Donny Darko 30 April 2023 08:02:39
    Name: Gas Haier Falco L1P20-F21T 17.6 kW double-circuit; Catalog: Heating boilers