Change history for item: Gas Bosch Gaz 7000 W ZWC 35-3 MFA

  1. Donny Darko 07 July 2023 14:39:29
    1. Create: Description #3318662
      Value: Type of heating boiler: gas, max. heating power: 33.30 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3318663
      Value: Gas, convection
    3. Create: Burner #3318664
      Value: Gas
    4. Create: Number of circuits #3318665
      Value: Double-circuit
    5. Create: Thermal power #3318666
      Value: 12.10 - 33.30 kW
    6. Create: Thermal load #3318667
      Value: 13.80 - 36.50 kW
    7. Create: The combustion chamber #3318668
      Value: Closed
    8. Create: Control #3318669
      Value: Electronic
    9. Create: Installation #3318670
      Value: Wall-mounted
    10. Create: Mains voltage #3318671
      Value: Single-phase
    11. Create: Peculiarities #3318672
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    12. Create: Expansion tank volume #3318673
      Value: 8 l
    13. Create: Equipment #3318674
      Value: Display
    14. Create: Fuel #3318675
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3318676
      Value: 4 cu. m/hour
    16. Create: LPG consumption #3318677
      Value: 2.9 kg/hour
    17. Create: Nominal pressure of natural gas #3318678
      Value: 7 - 30 mbar
    18. Create: Permissible LPG pressure #3318679
      Value: 37 mbar
    19. Create: Heat carrier temperature #3318680
      Value: 40 - 85 °С
    20. Create: Temperature in the DHW circuit #3318681
      Value: 40 - 65 °С
    21. Create: Hot water capacity at t 20°C #3318682
      Value: 23.9 l/min
    22. Create: Hot water capacity at t 30°C #3318683
      Value: 15.9 l/min
    23. Create: Hot water capacity at t 50°C #3318684
      Value: 9.5 l/min
    24. Create: Max. water pressure in the DHW circuit #3318685
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3318686
      Value: 3 bar
    26. Create: Gas connection #3318687
      Value: 3/4"
    27. Create: Heating circuit connection #3318688
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3318689
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3318690
      Value: 60/100 mm
    30. Create: Dimensions WxHxD #3318691
      Value: 480x825x370 mm
    31. Create: Weight #3318692
      Value: 47.7 kg
    32. Create: Additional Information #3318693
      Value: Admissible pressure of liquefied gas - butane 30 mbar
    33. Create: Image #6303174
      URL: https://avatars.mds.yandex.net/get-mpic/4342845/img_id6679123540120840328.jpeg/orig
    34. Create: Image #6303175
      URL: https://avatars.mds.yandex.net/get-mpic/4472189/img_id1447199403220064108.png/orig
    35. Create: Image #6303176
      URL: https://avatars.mds.yandex.net/get-mpic/7519991/img_id8915079462041105076.jpeg/orig
    36. Create: Image #6303177
      URL: https://avatars.mds.yandex.net/get-mpic/1705137/img_id1487046386268385428.jpeg/orig
    37. Create: Image #6303178
      URL: https://avatars.mds.yandex.net/get-mpic/2017233/img_id6914939480382982451.png/orig
    38. Create: Image #6303179
      URL: https://avatars.mds.yandex.net/get-mpic/5218923/img_id4148090512369605204.jpeg/orig
    39. Create: Preview image #6303180
      URL: https://avatars.mds.yandex.net/get-mpic/4342845/img_id6679123540120840328.jpeg/orig
  2. Donny Darko 30 April 2023 08:02:20
    Name: Gas Bosch Gaz 7000 W ZWC 35-3 MFA; Catalog: Heating boilers