Change history for item: Gas Bosch Gaz 7000 W ZWC 28-3 MFA

  1. Donny Darko 07 July 2023 14:39:24
    1. Create: Description #3318627
      Value: Type of heating boiler: gas, max. heating power: 28.10 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3318628
      Value: Gas, convection
    3. Create: Burner #3318629
      Value: Gas
    4. Create: Number of circuits #3318630
      Value: Double-circuit
    5. Create: Thermal power #3318631
      Value: 11.30 - 28.10 kW
    6. Create: Thermal load #3318632
      Value: 12.90 - 31.30 kW
    7. Create: The combustion chamber #3318633
      Value: Closed
    8. Create: Heated area #3318634
      Value: 280 sq.m
    9. Create: Efficiency #3318635
      Value: 92 %
    10. Create: Control #3318636
      Value: Electronic
    11. Create: Installation #3318637
      Value: Wall-mounted
    12. Create: Primary heat exchanger material #3318638
      Value: Copper
    13. Create: Mains voltage #3318639
      Value: Single-phase
    14. Create: Peculiarities #3318640
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    15. Create: Expansion tank volume #3318641
      Value: 8 l
    16. Create: Equipment #3318642
      Value: Display
    17. Create: Fuel #3318643
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3318644
      Value: 3.2 cu. m/hour
    19. Create: LPG consumption #3318645
      Value: 2.4 kg/hour
    20. Create: Nominal pressure of natural gas #3318646
      Value: 7 - 30 mbar
    21. Create: Permissible LPG pressure #3318647
      Value: 37 mbar
    22. Create: Heat carrier temperature #3318648
      Value: 40 - 85 °С
    23. Create: Temperature in the DHW circuit #3318649
      Value: 40 - 65 °С
    24. Create: Hot water capacity at t 20°C #3318650
      Value: 20.1 l/min
    25. Create: Hot water capacity at t 30°C #3318651
      Value: 13.4 l/min
    26. Create: Hot water capacity at t 50°C #3318652
      Value: 8.1 l/min
    27. Create: Max. water pressure in the DHW circuit #3318653
      Value: 10 bar
    28. Create: Max. water pressure in the heating circuit #3318654
      Value: 3 bar
    29. Create: Gas connection #3318655
      Value: 3/4"
    30. Create: Heating circuit connection #3318656
      Value: 3/4"
    31. Create: Branch pipe for connecting the DHW circuit #3318657
      Value: 1/2"
    32. Create: Coaxial chimney diameter #3318658
      Value: 60/100 mm
    33. Create: Dimensions WxHxD #3318659
      Value: 440x825x370 mm
    34. Create: Weight #3318660
      Value: 44.5 kg
    35. Create: Additional Information #3318661
      Value: Admissible pressure of liquefied gas - butane 30 mbar
    36. Create: Image #6303167
      URL: https://avatars.mds.yandex.net/get-mpic/4343092/img_id6294001765683636162.jpeg/orig
    37. Create: Image #6303168
      URL: https://avatars.mds.yandex.net/get-mpic/7519991/img_id8915079462041105076.jpeg/orig
    38. Create: Image #6303169
      URL: https://avatars.mds.yandex.net/get-mpic/5351166/img_id5582393287685689401.png/orig
    39. Create: Image #6303170
      URL: https://avatars.mds.yandex.net/get-mpic/5131700/img_id9161308403618418804.jpeg/orig
    40. Create: Image #6303171
      URL: https://avatars.mds.yandex.net/get-mpic/2017233/img_id6914939480382982451.png/orig
    41. Create: Image #6303172
      URL: https://avatars.mds.yandex.net/get-mpic/4615588/img_id2788340324821979515.jpeg/orig
    42. Create: Preview image #6303173
      URL: https://avatars.mds.yandex.net/get-mpic/4343092/img_id6294001765683636162.jpeg/orig
  2. Donny Darko 30 April 2023 08:02:19
    Name: Gas Bosch Gaz 7000 W ZWC 28-3 MFA; Catalog: Heating boilers