Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 14:39:24
Create:
Description #3318627
Value: Type of heating boiler: gas, max. heating power: 28.10 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3318628
Value: Gas, convection
Create:
Burner #3318629
Value: Gas
Create:
Number of circuits #3318630
Value: Double-circuit
Create:
Thermal power #3318631
Value: 11.30 - 28.10 kW
Create:
Thermal load #3318632
Value: 12.90 - 31.30 kW
Create:
The combustion chamber #3318633
Value: Closed
Create:
Heated area #3318634
Value: 280 sq.m
Create:
Efficiency #3318635
Value: 92 %
Create:
Control #3318636
Value: Electronic
Create:
Installation #3318637
Value: Wall-mounted
Create:
Primary heat exchanger material #3318638
Value: Copper
Create:
Mains voltage #3318639
Value: Single-phase
Create:
Peculiarities #3318640
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3318641
Value: 8 l
Create:
Equipment #3318642
Value: Display
Create:
Fuel #3318643
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3318644
Value: 3.2 cu. m/hour
Create:
LPG consumption #3318645
Value: 2.4 kg/hour
Create:
Nominal pressure of natural gas #3318646
Value: 7 - 30 mbar
Create:
Permissible LPG pressure #3318647
Value: 37 mbar
Create:
Heat carrier temperature #3318648
Value: 40 - 85 °С
Create:
Temperature in the DHW circuit #3318649
Value: 40 - 65 °С
Create:
Hot water capacity at t 20°C #3318650
Value: 20.1 l/min
Create:
Hot water capacity at t 30°C #3318651
Value: 13.4 l/min
Create:
Hot water capacity at t 50°C #3318652
Value: 8.1 l/min
Create:
Max. water pressure in the DHW circuit #3318653
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3318654
Value: 3 bar
Create:
Gas connection #3318655
Value: 3/4"
Create:
Heating circuit connection #3318656
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3318657
Value: 1/2"
Create:
Coaxial chimney diameter #3318658
Value: 60/100 mm
Create:
Dimensions WxHxD #3318659
Value: 440x825x370 mm
Create:
Weight #3318660
Value: 44.5 kg
Create:
Additional Information #3318661
Value: Admissible pressure of liquefied gas - butane 30 mbar
Create:
Image #6303167
URL: https://avatars.mds.yandex.net/get-mpic/4343092/img_id6294001765683636162.jpeg/orig
Create:
Image #6303168
URL: https://avatars.mds.yandex.net/get-mpic/7519991/img_id8915079462041105076.jpeg/orig
Create:
Image #6303169
URL: https://avatars.mds.yandex.net/get-mpic/5351166/img_id5582393287685689401.png/orig
Create:
Image #6303170
URL: https://avatars.mds.yandex.net/get-mpic/5131700/img_id9161308403618418804.jpeg/orig
Create:
Image #6303171
URL: https://avatars.mds.yandex.net/get-mpic/2017233/img_id6914939480382982451.png/orig
Create:
Image #6303172
URL: https://avatars.mds.yandex.net/get-mpic/4615588/img_id2788340324821979515.jpeg/orig
Create:
Preview image #6303173
URL: https://avatars.mds.yandex.net/get-mpic/4343092/img_id6294001765683636162.jpeg/orig
Donny Darko 30 April 2023 08:02:19
Name: Gas Bosch Gaz 7000 W ZWC 28-3 MFA; Catalog: Heating boilers