      Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3318596
      Value: Gas, convection
    3. Create: Burner #3318597
      Value: Gas
    4. Create: Number of circuits #3318598
      Value: Double-circuit
    5. Create: Thermal power #3318599
      Value: 7.30 - 24 kW
    6. Create: Thermal load #3318600
      Value: 8.40 - 26.70 kW
    7. Create: The combustion chamber #3318601
      Value: Closed
    8. Create: Control #3318602
      Value: Electronic
    9. Create: Installation #3318603
      Value: Wall-mounted
    10. Create: Mains voltage #3318604
      Value: Single-phase
    11. Create: Peculiarities #3318605
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    12. Create: Expansion tank volume #3318606
      Value: 8 l
    13. Create: Equipment #3318607
      Value: Display
    14. Create: Fuel #3318608
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3318609
      Value: 2.8 cu. m/hour
    16. Create: LPG consumption #3318610
      Value: 2 kg/hour
    17. Create: Nominal pressure of natural gas #3318611
      Value: 7 - 30 mbar
    18. Create: Permissible LPG pressure #3318612
      Value: 37 mbar
    19. Create: Heat carrier temperature #3318613
      Value: 40 - 85 °С
    20. Create: Temperature in the DHW circuit #3318614
      Value: 40 - 65 °С
    21. Create: Hot water capacity at t 20°C #3318615
      Value: 17.2 l/min
    22. Create: Hot water capacity at t 30°C #3318616
      Value: 11.5 l/min
    23. Create: Hot water capacity at t 50°C #3318617
      Value: 6.9 l/min
    24. Create: Max. water pressure in the DHW circuit #3318618
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3318619
      Value: 3 bar
    26. Create: Gas connection #3318620
      Value: 3/4"
    27. Create: Heating circuit connection #3318621
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3318622
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3318623
      Value: 60/100 mm
    30. Create: Dimensions WxHxD #3318624
      Value: 400x825x370 mm
    31. Create: Weight #3318625
      Value: 42.9 kg
    32. Create: Additional Information #3318626
      Value: Admissible pressure of liquefied gas - butane 30 mbar
    33. Create: Image #6303162
      URL: https://avatars.mds.yandex.net/get-mpic/4559636/img_id1439952487368073233.jpeg/orig
    34. Create: Image #6303163
      URL: https://avatars.mds.yandex.net/get-mpic/4472189/img_id1447199403220064108.png/orig
    35. Create: Image #6303164
      URL: https://avatars.mds.yandex.net/get-mpic/2017233/img_id6914939480382982451.png/orig
    36. Create: Image #6303165
      URL: https://avatars.mds.yandex.net/get-mpic/5228105/img_id6426807518819142092.jpeg/orig
    37. Create: Preview image #6303166
      URL: https://avatars.mds.yandex.net/get-mpic/4559636/img_id1439952487368073233.jpeg/orig
  2. Donny Darko 30 April 2023 08:02:19
    Name: Gas Bosch Gaz 7000 W ZWC 24-3 MFA; Catalog: Heating boilers