Change history for item: Gas Bosch Gaz 7000 W ZWC 28-3 MFK

  1. Donny Darko 07 July 2023 14:38:40
    1. Create: Description #3318503
      Value: Type of heating boiler: gas, max. thermal power: 27 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3318504
      Value: Gas, convection
    3. Create: Burner #3318505
      Value: Gas
    4. Create: Number of circuits #3318506
      Value: Double-circuit
    5. Create: Thermal power #3318507
      Value: 8.30 - 27 kW
    6. Create: Thermal load #3318508
      Value: 9.40 - 30 kW
    7. Create: The combustion chamber #3318509
      Value: Open
    8. Create: Control #3318510
      Value: Electronic
    9. Create: Installation #3318511
      Value: Wall-mounted
    10. Create: Mains voltage #3318512
      Value: Single-phase
    11. Create: Peculiarities #3318513
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    12. Create: Expansion tank volume #3318514
      Value: 8 l
    13. Create: Equipment #3318515
      Value: Display
    14. Create: Fuel #3318516
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3318517
      Value: 3.1 cu. m/hour
    16. Create: LPG consumption #3318518
      Value: 2.3 kg/hour
    17. Create: Nominal pressure of natural gas #3318519
      Value: 7 - 30 mbar
    18. Create: Permissible LPG pressure #3318520
      Value: 37 mbar
    19. Create: Max. coolant temperature #3318521
      Value: 85 °С
    20. Create: Temperature in the DHW circuit #3318522
      Value: 40 - 65 °С
    21. Create: Hot water capacity at t 20°C #3318523
      Value: 17.1 l/min
    22. Create: Hot water capacity at t 30°C #3318524
      Value: 11.4 l/min
    23. Create: Hot water capacity at t 50°C #3318525
      Value: 6.8 l/min
    24. Create: Max. water pressure in the DHW circuit #3318526
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3318527
      Value: 3 bar
    26. Create: Gas connection #3318528
      Value: 3/4"
    27. Create: Heating circuit connection #3318529
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3318530
      Value: 1/2"
    29. Create: Chimney diameter #3318531
      Value: 130 mm
    30. Create: Dimensions WxHxD #3318532
      Value: 400x825x370 mm
    31. Create: Weight #3318533
      Value: 38.8 kg
    32. Create: Additional Information #3318534
      Value: Admissible pressure of liquefied gas butane 30 mbar
    33. Create: Image #6303151
      URL: https://avatars.mds.yandex.net/get-mpic/1642819/img_id9222606514685863304/orig
    34. Create: Image #6303152
      URL: https://avatars.mds.yandex.net/get-mpic/4732637/img_id5225624634326031539.jpeg/orig
    35. Create: Image #6303153
      URL: https://avatars.mds.yandex.net/get-mpic/1865974/img_id5871435345235665485.jpeg/orig
    36. Create: Image #6303154
      URL: https://avatars.mds.yandex.net/get-mpic/4547325/img_id1364015918566735072.jpeg/orig
    37. Create: Preview image #6303155
      URL: https://avatars.mds.yandex.net/get-mpic/1642819/img_id9222606514685863304/orig
  2. Donny Darko 30 April 2023 08:02:16
    Name: Gas Bosch Gaz 7000 W ZWC 28-3 MFK; Catalog: Heating boilers