Change history for item: Gas Bosch Gaz 3000 W ZW 24-2 DH AE

  1. Donny Darko 07 July 2023 14:38:06
    1. Create: Description #3318298
      Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3318299
      Value: Gas, convection
    3. Create: Burner #3318300
      Value: Gas
    4. Create: Number of circuits #3318301
      Value: Double-circuit
    5. Create: Thermal power #3318302
      Value: 7 - 24 kW
    6. Create: Thermal load #3318303
      Value: 8.40 - 26.50 kW
    7. Create: The combustion chamber #3318304
      Value: Closed
    8. Create: Control #3318305
      Value: Electronic
    9. Create: Installation #3318306
      Value: Wall-mounted
    10. Create: Mains voltage #3318307
      Value: Single-phase
    11. Create: Peculiarities #3318308
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter, gas filter
    12. Create: Expansion tank volume #3318309
      Value: 6 l
    13. Create: Equipment #3318310
      Value: Display
    14. Create: Fuel #3318311
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3318312
      Value: 2.8 cu. m/hour
    16. Create: LPG consumption #3318313
      Value: 2.1 kg/hour
    17. Create: Nominal pressure of natural gas #3318314
      Value: 16 mbar
    18. Create: Permissible LPG pressure #3318315
      Value: 37 mbar
    19. Create: Heat carrier temperature #3318316
      Value: 45 - 88 °С
    20. Create: Temperature in the DHW circuit #3318317
      Value: 40 - 60 °С
    21. Create: Hot water capacity at t 30°C #3318318
      Value: 11.8 l/min
    22. Create: Hot water capacity at t 50°C #3318319
      Value: 6.9 l/min
    23. Create: Max. water pressure in the DHW circuit #3318320
      Value: 10 bar
    24. Create: Max. water pressure in the heating circuit #3318321
      Value: 3 bar
    25. Create: Gas connection #3318322
      Value: 3/4"
    26. Create: Heating circuit connection #3318323
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3318324
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3318325
      Value: 60/100 mm
    29. Create: Dimensions WxHxD #3318326
      Value: 400x700x298 mm
    30. Create: Weight #3318327
      Value: 33 kg
    31. Create: Image #6303127
      URL: https://avatars.mds.yandex.net/get-mpic/1911047/img_id3252188915322978803/orig
    32. Create: Preview image #6303128
      URL: https://avatars.mds.yandex.net/get-mpic/1911047/img_id3252188915322978803/orig
  2. Donny Darko 30 April 2023 08:02:14
    Name: Gas Bosch Gaz 3000 W ZW 24-2 DH AE; Catalog: Heating boilers