Change history for item: Electrolux GCB 11 Basic X Fi

  1. Donny Darko 07 July 2023 14:35:50
    1. Create: Description #3317520
      Value: Type of heating boiler: gas, max. thermal power: 11 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3317521
      Value: Gas, convection
    3. Create: Burner #3317522
      Value: Gas
    4. Create: Number of circuits #3317523
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3317524
      Value: 4.70 - 11 kW
    6. Create: Thermal load #3317525
      Value: 5.10 - 12 kW
    7. Create: The combustion chamber #3317526
      Value: Closed
    8. Create: Efficiency #3317527
      Value: 92 %
    9. Create: Control #3317528
      Value: Electronic
    10. Create: Installation #3317529
      Value: Wall-mounted
    11. Create: Mains voltage #3317530
      Value: Single-phase
    12. Create: Peculiarities #3317531
      Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3317532
      Value: 6 l
    14. Create: Equipment #3317533
      Value: Display, room thermostat
    15. Create: Fuel #3317534
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3317535
      Value: 1.24 cu. m/hour
    17. Create: LPG consumption #3317536
      Value: 0.99 kg/hour
    18. Create: Nominal pressure of natural gas #3317537
      Value: 13 - 20 mbar
    19. Create: Permissible LPG pressure #3317538
      Value: 37 mbar
    20. Create: Heat carrier temperature #3317539
      Value: 40 - 85 °С
    21. Create: Temperature in the DHW circuit #3317540
      Value: 30 - 60 °С
    22. Create: Hot water capacity at t 25°C #3317541
      Value: 10.3 l/min
    23. Create: Max. water pressure in the DHW circuit #3317542
      Value: 6 bar
    24. Create: Max. water pressure in the heating circuit #3317543
      Value: 3 bar
    25. Create: Gas connection #3317544
      Value: 3/4"
    26. Create: Heating circuit connection #3317545
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3317546
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3317547
      Value: 60/100 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3317548
      Value: Yes
    30. Create: Dimensions WxHxD #3317549
      Value: 403x725x325mm
    31. Create: Weight #3317550
      Value: 34 kg
    32. Create: Image #6302972
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id2807621881429640289/orig
    33. Create: Preview image #6302973
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id2807621881429640289/orig
  2. Donny Darko 30 April 2023 08:02:08
    Name: Electrolux GCB 11 Basic X Fi; Catalog: Heating boilers