Change history for item: Electrolux FSB 40 Mi/HW 44.4 kW double circuit

  1. Donny Darko 07 July 2023 14:35:35
    1. Create: Description #3317397
      Value: Type of heating boiler: gas, max. heating power: 44.40 kW, number of circuits: double-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of supply: single-phase,
    2. Create: Type of heating boiler #3317398
      Value: Gas, convection
    3. Create: Burner #3317399
      Value: Gas
    4. Create: Number of circuits #3317400
      Value: Double-circuit
    5. Create: Max. thermal power #3317401
      Value: 44.40 kW
    6. Create: Max. thermal load #3317402
      Value: 36.80 kW
    7. Create: The combustion chamber #3317403
      Value: Open
    8. Create: Heated area #3317404
      Value: 370 sq.m
    9. Create: Efficiency #3317405
      Value: 90.8 %
    10. Create: Control #3317406
      Value: Electronic
    11. Create: Installation #3317407
      Value: Floor
    12. Create: Primary heat exchanger material #3317408
      Value: Cast iron
    13. Create: Mains voltage #3317409
      Value: Single-phase
    14. Create: Peculiarities #3317410
      Value: Pressure gauge, external control connector, thermometer
    15. Create: The volume of the built-in boiler #3317411
      Value: 100 l
    16. Create: Equipment #3317412
      Value: Built-in boiler, display
    17. Create: Fuel #3317413
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3317414
      Value: 4.3 cu. m/hour
    19. Create: LPG consumption #3317415
      Value: 3.1 kg/hour
    20. Create: Nominal pressure of natural gas #3317416
      Value: 20 - 25 mbar
    21. Create: Permissible LPG pressure #3317417
      Value: 29 mbar
    22. Create: Heat carrier temperature #3317418
      Value: 45 - 85 °С
    23. Create: Max. temperature in the DHW circuit #3317419
      Value: 60 °С
    24. Create: Max. water pressure in the heating circuit #3317420
      Value: 4 bar
    25. Create: Gas connection #3317421
      Value: 3/4"
    26. Create: Heating circuit connection #3317422
      Value: 1"
    27. Create: Branch pipe for connecting the DHW circuit #3317423
      Value: 1/2"
    28. Create: Chimney diameter #3317424
      Value: 150 mm
    29. Create: Dimensions WxHxD #3317425
      Value: 635x1473x635 mm
    30. Create: Weight #3317426
      Value: 190 kg
    31. Create: Image #6302963
      URL: https://avatars.mds.yandex.net/get-mpic/4343059/img_id3359815087826308942.jpeg/orig
    32. Create: Preview image #6302964
      URL: https://avatars.mds.yandex.net/get-mpic/4343059/img_id3359815087826308942.jpeg/orig
  2. Donny Darko 30 April 2023 08:02:07
    Name: Electrolux FSB 40 Mi/HW 44.4 kW double circuit; Catalog: Heating boilers