Change history for item: Electrolux GCB-Q 32Fi

  1. Donny Darko 07 July 2023 14:34:17
    1. Create: Description #3316891
      Value: Type of heating boiler: gas, max. heating power: 31.60 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3316892
      Value: Gas, convection
    3. Create: Burner #3316893
      Value: Gas
    4. Create: Number of circuits #3316894
      Value: Double-circuit
    5. Create: Thermal power #3316895
      Value: 6.90 - 31.60 kW
    6. Create: Thermal load #3316896
      Value: 7.40 - 33.90 kW
    7. Create: The combustion chamber #3316897
      Value: Closed
    8. Create: Efficiency #3316898
      Value: 93.1 %
    9. Create: Control #3316899
      Value: Electronic
    10. Create: Installation #3316900
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3316901
      Value: Copper
    12. Create: Mains voltage #3316902
      Value: Single-phase
    13. Create: Peculiarities #3316903
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, external control connector, thermometer, water filter
    14. Create: Expansion tank volume #3316904
      Value: 6 l
    15. Create: Equipment #3316905
      Value: Display
    16. Create: Fuel #3316906
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3316907
      Value: 3.59 cu. m/hour
    18. Create: LPG consumption #3316908
      Value: 2.67 kg/h
    19. Create: Nominal pressure of natural gas #3316909
      Value: 17 - 25 mbar
    20. Create: Permissible LPG pressure #3316910
      Value: 37 mbar
    21. Create: Heat carrier temperature #3316911
      Value: 38 - 85 °С
    22. Create: Temperature in the DHW circuit #3316912
      Value: 35 - 55 °С
    23. Create: Hot water capacity at t 25°C #3316913
      Value: 20 l/min
    24. Create: Max. water pressure in the DHW circuit #3316914
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3316915
      Value: 3 bar
    26. Create: Gas connection #3316916
      Value: 3/4"
    27. Create: Heating circuit connection #3316917
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3316918
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3316919
      Value: 60/100 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3316920
      Value: Yes
    31. Create: Dimensions WxHxD #3316921
      Value: 400x703x325 mm
    32. Create: Weight #3316922
      Value: 33.6 kg
    33. Create: Image #6302926
      URL: https://avatars.mds.yandex.net/get-mpic/3741589/img_id3028708008605544852.jpeg/orig
    34. Create: Preview image #6302927
      URL: https://avatars.mds.yandex.net/get-mpic/3741589/img_id3028708008605544852.jpeg/orig
  2. Donny Darko 30 April 2023 08:02:02
    Name: Electrolux GCB-Q 32Fi; Catalog: Heating boilers