Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 07 July 2023 14:34:06
Create:
Description #3316823
Value: Type of heating boiler: gas, max. thermal power: 24.10 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase,
Create:
Type of heating boiler #3316824
Value: Gas, convection
Create:
Burner #3316825
Value: Gas
Create:
Number of circuits #3316826
Value: Double-circuit
Create:
Thermal power #3316827
Value: 5.30 - 24.10 kW
Create:
Thermal load #3316828
Value: 5.80 - 26.60 kW
Create:
The combustion chamber #3316829
Value: Open
Create:
Heated area #3316830
Value: 220 sq.m
Create:
Efficiency #3316831
Value: 90.8 %
Create:
Control #3316832
Value: Electronic
Create:
Installation #3316833
Value: Wall-mounted
Create:
Primary heat exchanger material #3316834
Value: Copper
Create:
Secondary heat exchanger material #3316835
Value: Stainless steel
Create:
Mains voltage #3316836
Value: Single-phase
Create:
Peculiarities #3316837
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
Expansion tank volume #3316838
Value: 6 l
Create:
Equipment #3316839
Value: Outdoor temperature sensor, display
Create:
Fuel #3316840
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3316841
Value: 2.82 cu. m/hour
Create:
LPG consumption #3316842
Value: 2.1 kg/hour
Create:
Nominal pressure of natural gas #3316843
Value: 3 - 25 mbar
Create:
Permissible LPG pressure #3316844
Value: 37 mbar
Create:
Heat carrier temperature #3316845
Value: 38 - 85 °С
Create:
Temperature in the DHW circuit #3316846
Value: 35 - 55 °С
Create:
Hot water capacity at t 25°C #3316847
Value: 13.8 l/min
Create:
Hot water capacity at t 30°C #3316848
Value: 11.5 l/min
Create:
Max. water pressure in the DHW circuit #3316849
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3316850
Value: 3 bar
Create:
Gas connection #3316851
Value: 3/4"
Create:
Heating circuit connection #3316852
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3316853
Value: 1/2"
Create:
Chimney diameter #3316854
Value: 130 mm
Create:
Dimensions WxHxD #3316855
Value: 400x703x325 mm
Create:
Weight #3316856
Value: 30.7 kg
Create:
Image #6302922
URL: https://avatars.mds.yandex.net/get-mpic/1525355/img_id6151190409379084753/orig
Create:
Preview image #6302923
URL: https://avatars.mds.yandex.net/get-mpic/1525355/img_id6151190409379084753/orig
Donny Darko 30 April 2023 08:02:02
Name: Electrolux GCB-Q 24i; Catalog: Heating boilers