Change history for item: Electrolux GCB-Q 24Fi

  1. Donny Darko 07 July 2023 14:34:01
    1. Create: Description #3316791
      Value: Type of heating boiler: gas, max. heating power: 23.70 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3316792
      Value: Gas, convection
    3. Create: Burner #3316793
      Value: Gas
    4. Create: Number of circuits #3316794
      Value: Double-circuit
    5. Create: Thermal power #3316795
      Value: 5.20 - 23.70 kW
    6. Create: Thermal load #3316796
      Value: 5.60 - 25.70 kW
    7. Create: The combustion chamber #3316797
      Value: Closed
    8. Create: Efficiency #3316798
      Value: 92.8 %
    9. Create: Control #3316799
      Value: Electronic
    10. Create: Installation #3316800
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3316801
      Value: Copper
    12. Create: Mains voltage #3316802
      Value: Single-phase
    13. Create: Peculiarities #3316803
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, external control connector, thermometer, water filter
    14. Create: Expansion tank volume #3316804
      Value: 6 l
    15. Create: Equipment #3316805
      Value: Display
    16. Create: Fuel #3316806
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3316807
      Value: 2.7 cu. m/hour
    18. Create: LPG consumption #3316808
      Value: 2.01 kg/h
    19. Create: Nominal pressure of natural gas #3316809
      Value: 17 - 25 mbar
    20. Create: Permissible LPG pressure #3316810
      Value: 37 mbar
    21. Create: Heat carrier temperature #3316811
      Value: 38 - 85 °С
    22. Create: Temperature in the DHW circuit #3316812
      Value: 35 - 55 °С
    23. Create: Hot water capacity at t 25°C #3316813
      Value: 15.2 l/min
    24. Create: Max. water pressure in the DHW circuit #3316814
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3316815
      Value: 3 bar
    26. Create: Gas connection #3316816
      Value: 3/4"
    27. Create: Heating circuit connection #3316817
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3316818
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3316819
      Value: 60/100 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3316820
      Value: Yes
    31. Create: Dimensions WxHxD #3316821
      Value: 400x703x325 mm
    32. Create: Weight #3316822
      Value: 31.7 kg
    33. Create: Image #6302920
      URL: https://avatars.mds.yandex.net/get-mpic/4700988/img_id3633395223294520968.jpeg/orig
    34. Create: Preview image #6302921
      URL: https://avatars.mds.yandex.net/get-mpic/4700988/img_id3633395223294520968.jpeg/orig
  2. Donny Darko 30 April 2023 08:02:02
    Name: Electrolux GCB-Q 24Fi; Catalog: Heating boilers