Change history for item: Electrolux GCB 30 Basic Duo Fi

  1. Donny Darko 07 July 2023 14:33:56
    1. Create: Description #3316758
      Value: Type of heating boiler: gas, max. heating power: 30.20 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3316759
      Value: Gas, convection
    3. Create: Burner #3316760
      Value: Gas
    4. Create: Number of circuits #3316761
      Value: Double-circuit
    5. Create: Thermal power #3316762
      Value: 7.80 - 30.20 kW
    6. Create: Thermal load #3316763
      Value: 8.50 - 32.80 kW
    7. Create: The combustion chamber #3316764
      Value: Closed
    8. Create: Heated area #3316765
      Value: 290 sq.m
    9. Create: Efficiency #3316766
      Value: 92 %
    10. Create: Control #3316767
      Value: Electronic
    11. Create: Installation #3316768
      Value: Wall-mounted
    12. Create: Primary heat exchanger material #3316769
      Value: Copper
    13. Create: Mains voltage #3316770
      Value: Single-phase
    14. Create: Peculiarities #3316771
      Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, connector for external control, thermometer
    15. Create: Expansion tank volume #3316772
      Value: 8 l
    16. Create: Equipment #3316773
      Value: Display, room thermostat
    17. Create: Fuel #3316774
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3316775
      Value: 3.3 cu. m/hour
    19. Create: LPG consumption #3316776
      Value: 2.4 kg/hour
    20. Create: Nominal pressure of natural gas #3316777
      Value: 25 mbar
    21. Create: Permissible LPG pressure #3316778
      Value: 37 mbar
    22. Create: Heat carrier temperature #3316779
      Value: 40 - 85 °С
    23. Create: Temperature in the DHW circuit #3316780
      Value: 30 - 60 °С
    24. Create: Hot water capacity at t 25°C #3316781
      Value: 17.2 l/min
    25. Create: Max. water pressure in the DHW circuit #3316782
      Value: 6 bar
    26. Create: Max. water pressure in the heating circuit #3316783
      Value: 3 bar
    27. Create: Gas connection #3316784
      Value: 3/4"
    28. Create: Heating circuit connection #3316785
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3316786
      Value: 1/2"
    30. Create: Coaxial chimney diameter #3316787
      Value: 60/100 mm
    31. Create: Connection of a separate chimney diameter 80 mm #3316788
      Value: Yes
    32. Create: Dimensions WxHxD #3316789
      Value: 403x725x325mm
    33. Create: Weight #3316790
      Value: 39 kg
    34. Create: Image #6302918
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id146502263496015096/orig
    35. Create: Preview image #6302919
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id146502263496015096/orig
  2. Donny Darko 30 April 2023 08:02:02
    Name: Electrolux GCB 30 Basic Duo Fi; Catalog: Heating boilers