Change history for item: Gas Thermex XANTUS HM24

  1. Donny Darko 07 July 2023 14:32:18
    1. Create: Description #3316239
      Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3316240
      Value: Gas, convection
    3. Create: Burner #3316241
      Value: Gas
    4. Create: Number of circuits #3316242
      Value: Double-circuit
    5. Create: Thermal power #3316243
      Value: 7 - 24 kW
    6. Create: The combustion chamber #3316244
      Value: Closed
    7. Create: Heated area #3316245
      Value: 240 sq.m
    8. Create: Efficiency #3316246
      Value: 93 %
    9. Create: Control #3316247
      Value: Electronic
    10. Create: Installation #3316248
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3316249
      Value: Copper
    12. Create: Secondary heat exchanger material #3316250
      Value: Stainless steel
    13. Create: Mains voltage #3316251
      Value: Single-phase
    14. Create: Peculiarities #3316252
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    15. Create: Expansion tank volume #3316253
      Value: 8 l
    16. Create: Equipment #3316254
      Value: Display
    17. Create: Fuel #3316255
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3316256
      Value: 2.49 cu. m/hour
    19. Create: Nominal pressure of natural gas #3316257
      Value: 13 mbar
    20. Create: Permissible LPG pressure #3316258
      Value: 30 mbar
    21. Create: Heat carrier temperature #3316259
      Value: 35 - 80 °С
    22. Create: Temperature in the DHW circuit #3316260
      Value: 30 - 60 °С
    23. Create: Hot water capacity at t 25°C #3316261
      Value: 12 l/min
    24. Create: Hot water capacity at t 30°C #3316262
      Value: 10.7 l/min
    25. Create: Max. water pressure in the DHW circuit #3316263
      Value: 10 bar
    26. Create: Max. water pressure in the heating circuit #3316264
      Value: 3 bar
    27. Create: Gas connection #3316265
      Value: 1/2"
    28. Create: Heating circuit connection #3316266
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3316267
      Value: 1/2"
    30. Create: Coaxial chimney diameter #3316268
      Value: 60/100 mm
    31. Create: Dimensions WxHxD #3316269
      Value: 420x725x288mm
    32. Create: Weight #3316270
      Value: 32.5 kg
    33. Create: Image #6302759
      URL: https://avatars.mds.yandex.net/get-mpic/4736439/img_id592487977284466833.jpeg/orig
    34. Create: Image #6302760
      URL: https://avatars.mds.yandex.net/get-mpic/5234200/img_id1853001365017744331.jpeg/orig
    35. Create: Preview image #6302761
      URL: https://avatars.mds.yandex.net/get-mpic/4736439/img_id592487977284466833.jpeg/orig
  2. Donny Darko 30 April 2023 08:01:56
    Name: Gas Thermex XANTUS HM24; Catalog: Heating boilers