Change history for item: Gas AEG GBT 124 23 kW double-circuit

  1. Donny Darko 07 July 2023 14:31:06
    1. Create: Description #3315898
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3315899
      Value: Gas, convection
    3. Create: Burner #3315900
      Value: Gas
    4. Create: Number of circuits #3315901
      Value: Double-circuit
    5. Create: Thermal power #3315902
      Value: 8.81 - 23 kW
    6. Create: Thermal load #3315903
      Value: 10 - 21.46 kW
    7. Create: The combustion chamber #3315904
      Value: Closed
    8. Create: Efficiency #3315905
      Value: 93.3 %
    9. Create: Control #3315906
      Value: Electronic
    10. Create: Installation #3315907
      Value: Wall-mounted
    11. Create: Mains voltage #3315908
      Value: Single-phase
    12. Create: Peculiarities #3315909
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3315910
      Value: 7 l
    14. Create: Equipment #3315911
      Value: Display
    15. Create: Fuel #3315912
      Value: Natural gas
    16. Create: Natural gas consumption #3315913
      Value: 2.41 cu. m/hour
    17. Create: Nominal pressure of natural gas #3315914
      Value: 13 mbar
    18. Create: Heat carrier temperature #3315915
      Value: 25 - 80 °C
    19. Create: Temperature in the DHW circuit #3315916
      Value: 35 - 60 °С
    20. Create: Hot water capacity at t 30°C #3315917
      Value: 10.25 l/min
    21. Create: Max. water pressure in the DHW circuit #3315918
      Value: 6 bar
    22. Create: Max. water pressure in the heating circuit #3315919
      Value: 3 bar
    23. Create: Gas connection #3315920
      Value: 3/4"
    24. Create: Heating circuit connection #3315921
      Value: 3/4"
    25. Create: Branch pipe for connecting the DHW circuit #3315922
      Value: 1/2"
    26. Create: Coaxial chimney diameter #3315923
      Value: 60/100 mm and 80/125 mm
    27. Create: Connection of a separate chimney diameter 80 mm #3315924
      Value: Yes
    28. Create: Dimensions WxHxD #3315925
      Value: 410x730x270 mm
    29. Create: Weight #3315926
      Value: 32 kg
    30. Create: Image #6302731
      URL: https://avatars.mds.yandex.net/get-mpic/4353087/img_id7583752944831354046.jpeg/orig
    31. Create: Preview image #6302732
      URL: https://avatars.mds.yandex.net/get-mpic/4353087/img_id7583752944831354046.jpeg/orig
  2. Donny Darko 30 April 2023 08:01:52
    Name: Gas AEG GBT 124 23 kW double-circuit; Catalog: Heating boilers