Change history for item: Gas AEG GBA 224 23.94 kW bypass

  1. Donny Darko 07 July 2023 14:30:55
    1. Create: Description #3315842
      Value: Type of heating boiler: gas, max. thermal power: 23.94 kW, number of circuits: double-circuit, location: wall-mounted, fuel: natural gas, type of combustion chamber: open, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3315843
      Value: Gas, convection
    3. Create: Burner #3315844
      Value: Gas
    4. Create: Number of circuits #3315845
      Value: Double-circuit
    5. Create: Thermal power #3315846
      Value: 11.03 - 23.94 kW
    6. Create: Thermal load #3315847
      Value: 12.72 - 26.60 kW
    7. Create: The combustion chamber #3315848
      Value: Open
    8. Create: Efficiency #3315849
      Value: 90 %
    9. Create: Control #3315850
      Value: Electronic
    10. Create: Installation #3315851
      Value: Wall-mounted
    11. Create: Mains voltage #3315852
      Value: Single-phase
    12. Create: Peculiarities #3315853
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3315854
      Value: 8 l
    14. Create: Equipment #3315855
      Value: Display
    15. Create: Fuel #3315856
      Value: Natural gas
    16. Create: Natural gas consumption #3315857
      Value: 2.82 cu. m/hour
    17. Create: Nominal pressure of natural gas #3315858
      Value: 13 mbar
    18. Create: Heat carrier temperature #3315859
      Value: 25 - 80 °C
    19. Create: Temperature in the DHW circuit #3315860
      Value: 35 - 60 °С
    20. Create: Hot water capacity at t 30°C #3315861
      Value: 11.4 l/min
    21. Create: Max. water pressure in the DHW circuit #3315862
      Value: 6 bar
    22. Create: Max. water pressure in the heating circuit #3315863
      Value: 3 bar
    23. Create: Gas connection #3315864
      Value: 3/4"
    24. Create: Heating circuit connection #3315865
      Value: 3/4"
    25. Create: Branch pipe for connecting the DHW circuit #3315866
      Value: 1/2"
    26. Create: Chimney diameter #3315867
      Value: 130 mm
    27. Create: Dimensions WxHxD #3315868
      Value: 450x850x330 mm
    28. Create: Weight #3315869
      Value: 38 kg
    29. Create: Image #6302727
      URL: https://avatars.mds.yandex.net/get-mpic/4303817/img_id906865137900734568.jpeg/orig
    30. Create: Preview image #6302728
      URL: https://avatars.mds.yandex.net/get-mpic/4303817/img_id906865137900734568.jpeg/orig
  2. Donny Darko 30 April 2023 08:01:51
    Name: Gas AEG GBA 224 23.94 kW bypass; Catalog: Heating boilers