| Weight: |
31.6 kg
|
| Depth: |
328 mm
|
| Equipment: |
Display
|
| Description: |
Type of heating boiler: gas, max. thermal power: 32.70 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, control: electronic, operating principle
|
| Width: |
482
|
| Height: |
652
|
| Control: |
Electronic
|
| Functions: |
Auto-diagnostics, auto-ignition, frost protection, overheating protection, switch-on indication, underfloor heating connection, programmer
|
| Efficiency: |
91 %
|
| Accommodation: |
Wall
|
| Power type: |
Single-phase
|
| Fuel: |
Natural gas
|
| Combustion chamber type: |
Closed
|
| Heated area: |
330 m²
|
| Minimum heat output: |
82 kW
|
| LPG consumption: |
3 kg/h
|
| Maximum coolant temperature: |
80°C
|
| Maximum temperature in the DHW circuit: |
60°C
|
| Maximum water pressure in the DHW circuit: |
10 bar
|
| Minimum temperature in the DHW circuit: |
30°C
|
| Expansion tank volume: |
7 l
|
| Burner: |
Gas
|
| Coaxial chimney diameter: |
60/100 mm
|
| Gas connection: |
3/4"
|
| Branch pipe for connecting the DHW circuit: |
3/4"
|
| Heating circuit connection: |
3/4"
|
| Separate chimney 80x80 mm: |
There is
|
| Permissible LPG pressure: |
28 mbar
|
| Nominal pressure of natural gas: |
20 mbar
|
| Natural gas consumption: |
3.8 m³/hour
|
| Number of circuits: |
Double-circuit
|
| Primary heat exchanger material: |
Copper
|
| The principle of operation of a gas boiler: |
Convection
|
| Type of heating boiler: |
Gas
|
| Max. thermal power: |
32.7 kW
|
| Maximum thermal load: |
35 kW
|
| Maximum water pressure in the heating circuit: |
10 bar
|
| Minimum heating medium temperature: |
30°C
|
| Minimum heat load: |
9.5 kW
|
| Hot water capacity at t 25°C: |
18.7 l/min
|