| Weight: |
37 kg
|
| Equipment: |
Display
|
| Description: |
Type of heating boiler: gas, max. heating power: 25.60 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
|
| Peculiarities: |
Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
|
| Control: |
Electronic
|
| Dimensions WxHxD: |
440x725x355 mm
|
| Installation: |
Wall-mounted
|
| Efficiency: |
102.5 %
|
| Fuel: |
Natural gas, liquefied gas
|
| Mains voltage: |
Single-phase
|
| LPG consumption: |
1.9 kg/hour
|
| The combustion chamber: |
Closed
|
| Max. water pressure in the DHW circuit: |
10 bar
|
| Max. water pressure in the heating circuit: |
3 bar
|
| Temperature in the DHW circuit: |
40 - 60 °С
|
| Heat carrier temperature: |
35 - 82 °С
|
| Expansion tank volume: |
8 l
|
| Burner: |
Gas
|
| Coaxial chimney diameter: |
60/100 mm and 80/125 mm
|
| Gas connection: |
3/4"
|
| Branch pipe for connecting the DHW circuit: |
1/2"
|
| Heating circuit connection: |
3/4"
|
| Permissible LPG pressure: |
35 mbar
|
| Nominal pressure of natural gas: |
10.50 - 16 mbar
|
| Natural gas consumption: |
2.6 cu. m/hour
|
| Number of circuits: |
Double-circuit
|
| Type of heating boiler: |
Gas, convection
|
| Max. thermal power: |
25.60 kW
|
| Hot water capacity at t 30°C: |
11.4 l/min
|