| Weight: |
125 kg
|
| Depth: |
640 mm
|
| Equipment: |
Display
|
| Description: |
Heating boiler type: gas, placement: floor standing, fuel: natural gas
|
| Width: |
484
|
| Height: |
1080
|
| Control: |
Mechanical
|
| Functions: |
Frost protection, overheating protection
|
| Efficiency: |
92 %
|
| Accommodation: |
Floor
|
| Fuel: |
Natural gas
|
| Combustion chamber type: |
Open
|
| Chimney diameter: |
180 mm
|
| Fuel consumption: |
4.5 kg/h
|
| Heated area: |
400 m²
|
| Maximum coolant temperature: |
90°C
|
| Gas connection: |
3/4"
|
| Heating circuit connection: |
2"
|
| Nominal pressure of natural gas: |
13 mbar
|
| Natural gas consumption: |
4.5 m³/hour
|
| Number of circuits: |
Single-loop
|
| Primary heat exchanger material: |
Steel
|
| The principle of operation of a gas boiler: |
Convection
|
| Type of heating boiler: |
Gas
|
| Max. thermal power: |
40 kW
|
| Maximum thermal load: |
40 kW
|
| Maximum water pressure in the heating circuit: |
3 bar
|
| Minimum heating medium temperature: |
40°C
|