Weight: 
                                                            348 kg
                             
                         
                                                                                                                            
                                                            
                                                            
                        VIDEO 
            
                             
                         
                                                                                                                            
                                                            Equipment: 
                                                            Built-in exhaust fan, display
                             
                         
                                                                                                                            
                                                            Description: 
                                                            Type of heating boiler: gas, max. heating power: 32.40 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
                             
                         
                                                                                
                                                                                        
                                                            Peculiarities: 
                                                            Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
                             
                         
                                                                                
                                                                                        
                                                            Control: 
                                                            Electronic
                             
                         
                                                                                                                            
                                                            Dimensions WxHxD: 
                                                            400x727x300mm
                             
                         
                                                                                
                                                                                        
                                                            Installation: 
                                                            Wall-mounted
                             
                         
                                                                                
                                                                                        
                                                            Efficiency: 
                                                            94 %
                             
                         
                                                                                
                                                                                        
                                                            Fuel: 
                                                            Natural gas, liquefied gas
                             
                         
                                                                                
                                                                                        
                                                            Mains voltage: 
                                                            Single-phase
                             
                         
                                                                                
                                                                                        
                                                            Thermal power: 
                                                            11.70 - 32.40 kW
                             
                         
                                                                                
                                                                                        
                                                            Fuel consumption: 
                                                            2.72 kg/hour
                             
                         
                                                                                
                                                                                        
                                                            Heated area: 
                                                            345 sq.m
                             
                         
                                                                                
                                                                                        
                                                            LPG consumption: 
                                                            2.67 kg/h
                             
                         
                                                                                
                                                                                        
                                                            Secondary heat exchanger material: 
                                                            Stainless steel
                             
                         
                                                                                
                                                                                        
                                                            The combustion chamber: 
                                                            Closed
                             
                         
                                                                                                                            
                                                            Max. water pressure in the DHW circuit: 
                                                            6 bar
                             
                         
                                                                                                                            
                                                            Max. water pressure in the heating circuit: 
                                                            3 bar
                             
                         
                                                                                                                            
                                                            Temperature in the DHW circuit: 
                                                            35 - 55 °С
                             
                         
                                                                                                                            
                                                            Heat carrier temperature: 
                                                            35 - 80 °С
                             
                         
                                                                                                                            
                                                            Thermal load: 
                                                            13.60 - 34.50 kW
                             
                         
                                                                                
                                                                                        
                                                            Expansion tank volume: 
                                                            8 l
                             
                         
                                                                                
                                                                                        
                                                            Burner: 
                                                            Gas
                             
                         
                                                                                
                                                                                        
                                                            Coaxial chimney diameter: 
                                                            60/100 mm
                             
                         
                                                                                                                            
                                                            Gas connection: 
                                                            3/4"
                             
                         
                                                                                                                            
                                                            Branch pipe for connecting the DHW circuit: 
                                                            1/2"
                             
                         
                                                                                                                            
                                                            Heating circuit connection: 
                                                            3/4"
                             
                         
                                                                                                                            
                                                            Connection of a separate chimney diameter 80 mm: 
                                                            Yes
                             
                         
                                                                                
                                                                                        
                                                            Permissible LPG pressure: 
                                                            35 mbar
                             
                         
                                                                                                                            
                                                            Nominal pressure of natural gas: 
                                                            17 - 25 mbar
                             
                         
                                                                                                                            
                                                            Natural gas consumption: 
                                                            3.65 cu. m/hour
                             
                         
                                                                                
                                                                                        
                                                            Number of circuits: 
                                                            Double-circuit
                             
                         
                                                                                                                            
                                                            Primary heat exchanger material: 
                                                            Copper
                             
                         
                                                                                                                            
                                                            Type of heating boiler: 
                                                            Gas, convection
                             
                         
                                                                                
                                                                                        
                                                            Hot water capacity at t 25°C: 
                                                            18.6 l/min
                             
                         
                                                                                                                            
                                                            Hot water capacity at t 30°C: 
                                                            15.5 l/min