                                                            | Weight: | 
                                                            160 kg
                             | 
                        
                                                                                                                            
                                                            | Description: | 
                                                            Boiler type: solid fuel, number of circuits: single circuit, max. heat output: 12 kW, heated area: 100 m², placement: floor, combustion chamber type: open, solid fuel operation principle
                             | 
                        
                                                                                
                                                                                        
                                                            | Control: | 
                                                            Mechanical
                             | 
                        
                                                                                                                            
                                                            | Dimensions WxHxD: | 
                                                            610x905x685 mm
                             | 
                        
                                                                                
                                                                                        
                                                            | Functions: | 
                                                            Thermometer, manometer
                             | 
                        
                                                                                
                                                                                        
                                                            | Installation: | 
                                                            Floor
                             | 
                        
                                                                                
                                                                                        
                                                            | Efficiency: | 
                                                            84 %
                             | 
                        
                                                                                
                                                                                        
                                                            | Fuel: | 
                                                            Firewood, coal, coal briquettes
                             | 
                        
                                                                                
                                                                                        
                                                            | Chimney diameter: | 
                                                            145 mm
                             | 
                        
                                                                                
                                                                                        
                                                            | Thermal power: | 
                                                            6 - 12 kW
                             | 
                        
                                                                                
                                                                                        
                                                            | Protection: | 
                                                            Safety valve, air vent
                             | 
                        
                                                                                
                                                                                        
                                                            | Fuel consumption: | 
                                                            3.2 kg/hour
                             | 
                        
                                                                                
                                                                                        
                                                            | Heated area: | 
                                                            100 sq.m
                             | 
                        
                                                                                
                                                                                        
                                                            | Heating element for temperature maintenance: | 
                                                            Optional
                             | 
                        
                                                                                
                                                                                        
                                                            | The combustion chamber: | 
                                                            Open
                             | 
                        
                                                                                                                            
                                                            | Max. water pressure in the heating circuit: | 
                                                            2 bar
                             | 
                        
                                                                                                                            
                                                            | Heat carrier temperature: | 
                                                            65 - 95 °С
                             | 
                        
                                                                                
                                                                                        
                                                            | Heating circuit connection: | 
                                                            2"
                             | 
                        
                                                                                
                                                                                        
                                                            | Number of circuits: | 
                                                            Single-loop
                             | 
                        
                                                                                                                            
                                                            | Primary heat exchanger material: | 
                                                            Steel
                             | 
                        
                                                                                                                            
                                                            | Type of heating boiler: | 
                                                            Solid fuel, classic
                             | 
                        
                                                                                                                            
                                                            | Non-volatile: | 
                                                            Yes
                             | 
                        
                                                                                
                                                                                        
                                                            | Recommended fuel: | 
                                                            Coal
                             |