| Weight: |
257 kg
|
| Description: |
Type of heating boiler: gas, max. thermal power: 100 kW, number of circuits: single-circuit, placement: floor, type of combustion chamber: open, control: mechanical, non-volatile
|
| Peculiarities: |
Safety valve
|
| Control: |
Mechanical
|
| Dimensions WxHxD: |
975x1180x734 mm
|
| Installation: |
Floor
|
| Efficiency: |
90 %
|
| Chimney diameter: |
200 mm
|
| Heated area: |
980 sq.m
|
| The combustion chamber: |
Open
|
| Max. water pressure in the heating circuit: |
3 bar
|
| Max. coolant temperature: |
90 °С
|
| Burner: |
Gas
|
| Gas connection: |
3/4"
|
| Heating circuit connection: |
2"
|
| Permissible LPG pressure: |
21 mbar
|
| Nominal pressure of natural gas: |
13 mbar
|
| Natural gas consumption: |
5.75 cu. m/hour
|
| Number of circuits: |
Single-loop
|
| Primary heat exchanger material: |
Steel
|
| Type of heating boiler: |
Gas
|
| Non-volatile: |
Yes
|
| Max. thermal power: |
100 kW
|